Setting the ground speed override (gso) value, Setting the field area alarm, Product volume (full load capacity) – TeeJet ARC-6000 User Manual
Page 21: Setting the full load capacity, Setting the full load capacity -11

2-11
98-0501
Rev.- 1
ARC 6000
CE & S
TANDARD
V
ERSION
To select the desired response:
A. Set the console switches to the following positions:
Power
ON
Mode Selector
OPERATE
Display Selector
IMPL WIDTH
Boom Switches
OFF
B. Hold the INC switch up to display the current response selected.
C. Continuing to hold the INC switch up causes the display to cycle between "Hold" and "Close" at about three second
intervals. The last option appearing in the display when the INC switch is released will be the response selected.
2.9. SETTING THE GROUND SPEED OVERRIDE (GSO) VALUE.
With the Display Selector set to the Speed position in the SETUP Mode, the console will display the current Ground Speed
Override value. This value can be changed using the INC/DEC switch. If you intend to use this feature, set the value to the
minimum Ground Speed you want to control to when the GSO switch is activated. This should be the lowest speed at which the
sprayer will operate smoothly and provide a good nozzle pattern. If you do not intend to use this feature, set this value to zero (0.0).
CAUTION: This feature causes the product to be applied at a rate consistent with the GSO speed, not the true ground
speed. Serious over application can occur, if not used properly.
2.10. SETTING THE FIELD AREA ALARM
Use the field area alarm to alert the operator as he accumulates specific area amounts. The console will flash and beep as each
area increment is accumulated.
An operator may use this feature to remind him to check his load to be certain it is disappearing at the correct rate. He also could
use this feature to double check acreage estimates.
A. Make sure all booms are OFF. Set the control console to the following switch settings:
Power
ON
Mode Selector
SETUP
Display Selector
FIELD AREA
The display will now show the current selected acreage increments.
B. Use the INC/DEC switch to set the desired acreage increments.
C. Return the Mode Selector switch to OPERATE to apply.
2.11. PRODUCT VOLUME (FULL LOAD CAPACITY)
2.11.1. SETTING THE FULL LOAD CAPACITY
The full load capacity of the vehicle can be preset in the control console so that it can be recalled as the vehicle is reloaded.
A. Make sure all booms are OFF. Set the control console to the following switch settings:
Power
ON
Mode Selector
SETUP
Display Selector
PRODUCT VOL.
The display will now show the current selected full load capacity.