B. Use the INC/DEC switch to set the desired full load capacity.

C. Return the Mode Selector switch to OPERATE to apply.

2.11.2. RECALLING THE FULL LOAD CAPACITY

Whenever PRODUCT VOL. is displayed in the OPERATE mode, the full load capacity of the vehicle can be recalled by
holding the INC switch up for at least three seconds.

2.11.3. SETTING A LOAD CAPACITY LESS THAN FULL LOAD

If a full load is not taken aboard the vehicle, the actual amount loaded can be set when PRODUCT VOL. is displayed in the
OPERATE mode by holding the DEC switch down (about three seconds) until the Product Vol. values start to decrease. Once
the numbers start to change, they can be set up or down using the INC/DEC switch until the actual load is displayed. Switching
out of the PRODUCT VOL. display will bring the control console back to normal operation.

2.12. SETTING AUTO POWER DOWN TIME

The console has an "Auto Power Down" feature which powers the console off after an operator selectable period (default is
30 min) has elapsed. If no input is received from the speed sensor or any console switch during this time the APD feature is
activated. The APD time can be set from 15 to 60 minutes. Selecting a period less than 15 minutes disables the APD feature.

A. Use the following switch settings to adjust the Auto Power down time:

Power

OFF

Mode selector

SET-UP

Display selector

% Rate

Hold the INC switch

UP while turning the power on

The display will show the current Auto Power Down time.

B. Select the desired time using the INC/DEC switch.

C. Exit this set-up mode by moving the Display Selector to another position, the Mode Selector to OPERATE, or

turning the console OFF and back ON.

NOTE: The “Auto Power Down Feature is only available on the CE version of the console (CE designation label on back of
console). If you have the standard console model always turn the console power off when not in use to prevent unnecessary