1.4. DISPLAY SELECTOR
The Display Selector (right center) is used to select and display the various console functions.
OFF
SET- UP
DEC.
ON
OPERATE
INC.
ARC-6000
Automatic
Rate Controller
MID-TECH
MIDWEST TECHNOLOGIES, INC.
1
2
3
4
5
6
7
8
9
%Rate
DISPLAY SELECTOR
Speed
Field Area
Impl.Width
Distance
Test
Speed
Prime
Total Applied
Application Rate
Scan
Total Area
Product Vol.
BOOMS
.
-Ac
Flow
RATE
Gal./
1
2
3
4
5
6
7
8
9
%Rate
DISPLAY SELECTOR
Speed
Field Area
Impl.Width
Distance
Test
Speed
Prime
Total Applied
Application Rate
Scan
Total Area
Product Vol.
BOOMS
¨
%Rate
DISPLAY SELECTOR
Speed
Field Area
Impl.Width
Distance
Test
Speed
Prime
Total Applied
Application Rate
Scan
Total Area
Product Vol.
OFF
SET- UP
ON
OPERATE
SET- UP
OPERATE
1.4.1. DISPLAY SELECTOR FUNCTIONS -OPERATE MODE (LIQUID APPLICATION)
SPEED: The current vehicle speed in tenths of a Mile per Hour.
FIELD AREA: Accumulated Area, in hundredths of an Acre.*
TOTAL AREA: Accumulated Area, in Acres.*
PRODUCT VOL.: Amount of product aboard the vehicle. Resets to a pre-programmed, full load by holding the INC
switch up with ground speed zero. Ground speed zero also allows setting any value using the INC/DEC switch. Value
counts down as the product is applied, an alarm sounds with ten percent left aboard.**
% RATE: The percent of programmed application rate at which the product is being applied. This percentage can be
changed up or down a preset amount by operating the INC/DEC switch.***
APPLICATION RATE: The desired application rate can be set with the INC/DEC switch when the ground speed is zero
or all booms are OFF.** Once application has commenced, and metered discharge is established, the actual measured
application rate will be displayed here. Also used to set the control valve to manual operation.
TOTAL APPLIED: The actual volume applied, as measured by the flowmeter or pressure sensor.*
IMPL. WIDTH: The active boom width in tenths of Feet. Depends on the actual boom sections selected “ON”.
DISTANCE: The accumulated distance in Feet, Miles after 5,280 Ft.*
PRIME: This position is used to lock the control valve open during main pump priming on a liquid system. Initially the
display will show a series of five dashes. Hold INC switch up for three seconds to lock the control valve fully open. The
display will read OPEN. Switching away from PRIME will cause the control valve to drive CLOSED. When operating
in the pressure based (Psi) mode, the current boom pressure is displayed here.
TEST SPEED: The speed the console will use for stationary tests of the sprayer. Use the INC/DEC switch to change this
value.**
SCAN: The display will scan SPEED, FIELD AREA, PRODUCT VOLUME, APPLICATION RATE, TOTAL APPLIED,
and, if in pressure based mode, BOOM PRESSURE. The display will hold at each position for approximately two
seconds before automatically cycling to the next.
NOTES:
* Totals can be zeroed in this mode.
** Values are programmable in this mode.
***Values changeable by a % increase or decrease.