beautypg.com

Changing units (liquid applicator only), Setting application rate, Setting the % rate change – TeeJet ARC-6000 User Manual

Page 12: Setting boom widths, Changing units (liquid applicator only) -2

background image

98-05017

Rev.- 1

2-2

ARC 6000

CE & S

TANDARD

V

ERSION

2.2.2. CHANGING UNITS (LIQUID APPLICATOR ONLY)

To change units, set the Mode switch to “OPERATE” and the Display Selector to “SPEED”. The current speed units will be
displayed. Holding the INC/DEC switch up or down (see chart) until the display changes (approximately 5 sec.) will set the units
accordingly.

UNITS

INC./DEC. Switch

English to Metric

DOWN

Metric to English

DOWN

English to Metrish

UP

Metrish to English

DOWN

NOTE: Metric to Metrish is not allowed. Convert to English first and then to Metrish.

2.3. SETTING APPLICATION RATE

The ARC system is designed to maintain a constant, pre-selected application rate. In order for the control console to do this, the
operator must enter the desired application rate.

A. Set the console switches to the following positions:

Power

ON

Mode Selector

OPERATE (Application rate is set in the Operate Mode!!!)

Display Selector

APPLICATION RATE

Ground Speed

ZERO

All Booms

OFF

The display will show the current application rate.

B. Use the INC/DEC switch to set the value displayed to the desired rate.

C. Setting the APPLICATION RATE to 0.0 will shut off the flow control function.

2.4. SETTING THE % RATE CHANGE

This feature allows the operator to change the application rate “On The Go”. Application rate is changed with a simple
actuation of the INC/DEC switch. The amount of change each switch actuation makes is proportional to the value pro-
grammed into this position, (e.g. 20 =20% change in the target rate). For example, if the liquid application rate is set at 10.0
gallons per acre, a single actuation of the INC switch will cause the valve to control flow at the rate of 12.0 gallons per acre
(10.0 + 20% = 12.0).

A. Set the console switches to the following positions:

Power

ON

Mode Selector

SETUP

Display Selector

% RATE

The display will show the current % change value.

B. Use the INC/DEC switch to set this number to the desired % change value.

2.5. SETTING BOOM WIDTHS

The MIDWEST TECHNOLOGIES control console is designed to automatically compensate for changes in the swath width,
caused by turning on or off boom sections. For the console to automatically respond to changes in swath width, it needs to
know the size of each boom section. Use the following procedure to set boom section widths.