SerialGate User Guide

94

RS232 (Seinal)

Change all the serial ports of a device server to RS-232, and conduct a serial signal test.

RS-232 Loopback connector must be connected to all the serial ports for the test.

If a user selects ‘yes’ option, it starts serial signal test and prints out the result on LCD.

T e s t I n g ( S I g n a l )

O O O O O O O O O O O O O O O O

If there is nothing wrong, it displays ‘O’ or ‘X’ otherwise.

RS422 (Loopback)

Change all the serial ports of a device server to RS-422, and conduct a Loopback test.

RS-422 Loopback connector must be connected to all the serial ports for the test.

If a user selects ‘yes’ option, it starts Loopback test and prints out the result on LCD.

T e s t I n g ( R S 4 2 2 )

O O O O O O O O O O O O O O O O

If there is nothing wrong, it displays ‘O’ or ‘X’ otherwise.

RS485 (Loopback)

Change all the serial ports of a device server to RS-485, and conduct a Loopback test.

No additional loopback connector is required for RS-485 since RS-485 supports self Loopback.

If a user selects ‘yes’ option, it starts Loopback test and prints out the result on LCD.

T e s t I n g ( R S 4 8 5 )

O O O O O O O O O O O O O O O O

If there is nothing wrong, it displays ‘O’ or ‘X’ otherwise.