Solvline SerialGate User Manual

Page 66

background image


SerialGate User Guide

66

Menu

Default

Descriptions

Baud Rate

9600 bps

Set communication speed.

(Options: 150, 300, 600, 1200, 2400, 4800, 9600, 19200, 38400,

57600, 115200, 230400, 460800, 921600 bps)

Data Bits

8

Set the number of bits in each character size.

(Options: 5, 6, 7, 8)

Stop Bits

1

Set the number of stop bits..

(Options: 1, 2)

Parity

None

Set parity bit check scheme..

(Options: None, Odd, Even)

Flow

Control

None

Set the flow control scheme.

(Options: None, Xon/Xoff, RTS/CTS)

Device Type DataOnly

Set the signal line checking method for the device to be connected to

the given serial port.

If the mode is set to Data Only, only TxD, RxD, and GND signal lines

are used in inter-device communication.

If the mode is set to Modem Signals, all modem signals except

RI(Ring Indicator) are asserted, tested, and used in communication.

(Options: Data Only, Modem Signals)

Remote IP

Address /

Port

0.0.0.0 /

4000

If the Operation Mode is in TCP Client or UDP Client or Pair_Master

mode, set the IP address and the socket number to connect to.

Keepalive

Check

Time

0

After a certain amount of time passes without any communication

after the socket connection between the given serial port and the

server is established, automatically disconnect the socket

connection. Valid from 0 to 32767 sec.

For example, if the operation mode is set to TCP Server and Alive

Check Time is configured to 10, TCP Server will listen for the client

’s

connection and eventually establish a connection. Since the check

time is 10 seconds, the server will wait for 10 seconds until the client

connected to it sends any packet. If there is no data for 10 seconds,

server will quit the connection and return to the listening state. This

option is helpful in preventing communication obstacles that occur

when either SerialGate or the client quits unexpectedly (i.e. Sudden