Verification

It verifies each interface HW of a device server.

In order to select System, press ‘ESC’ on the panel until ‘Main Menu’ comes up, and if ‘Main Manu’ is

displayed, press

‘<<’ or ‘>>’ until you see ‘Verification’. Then, press ‘Enter’ to change the details.

At anytime ‘ESC’ is selected, it moves to the top menu.

(*) When a user performs this test, all the program running in a device server stops. So, a user must

restart the device server after the test.

Menu

Option Default

Description

RS232(Loopback)

Cancel Yes

Cancel

<<, >> : Select option.

Enter : If Cancel selected, go to the next menu.

If Yes selected, that action is performed.

RS232(Signal)

RS422(Loopback)

RS485(Loopback)

Testing WAN Port

Testing LAN Port

Testing MMC

Testing Reset

Testing Console

Testing RTC

RS232 (Loopback)

Change all the serial ports of a device server to RS-232, and conduct a Loopback test.

RS-232 Loopback connector must be connected to all the serial ports for the test.

If a user selects ‘yes’ option, it starts Loopback test and prints out the result on LCD.

T e s t I n g ( R S 2 3 2 )

O O O O O O O O O O O O O O O O

If there is nothing wrong, it displays ‘O’ or ‘X’ otherwise.