7fig. 2 — 50rhr dimensional data, Left return right return, Unit hanger detail – Carrier AQUAZONE RVC User Manual
Page 7

7
Fig. 2 — 50RHR Dimensional Data
Front
K
M
Blower
Outlet
M
L
Right Return
Front
Left
Discharge
3
CSP
Back
Discharge
Condensate
3/4
“ FTP
3.25
F
Front-View
BSP
Air Coil
C
S
R
B
ASP
Q
P
Front
K
M
Blower
Outlet
J
L
Front
BSP
LEFT RETURN
RIGHT RETURN
Air Coil
CSP
Front
1.1
C
S
Q
P
R
B
Unit Hanger Detail
X
Y
F
ront
Z
Model X Y Z
006-024 43.1 24.375 20.375
030-036 53.1 24.375 20.375
042-048 62.1 24.375 20.375
060 71.1 27.375 23.375
B Configuration - Right Return Back Discharge
ASP
CSP
Front
Left Return
F
3.25
CSP
Condensate
3/4
“ FPT
ASP
3
‘ Service
Access
3
Right
Discharge
Back
Discharge
E Configuration - Left Return Back Discharge
Water
Connection
Water
Connection
2
‘ Service
Access
S Configuration - Left Return Right Discharge -
Air Coil Opening
3
‘
SERVICE
ACCESS
Right
View
Left
View
S Configuration - Left Return Right Discharge -
Air Coil Opening
Z Configuration - Right Return Left Discharge -
Air Coil Opening
Left
View
Right
View
Z Configuration - Right Return Left Discharge -
Air Coil Opening
N
BSP
O
M
C
A
Blower
Outlet
Air Coil
S
ide
L
1/2“
Knockout
Low Voltage
1/2“ Knockout
Power Supply
3/4“ Knockout
A
1.6 [40.6mm]
I
H
G
D
E
1
2
M
N
C
L
O
A
BSP
Air Coil
S
ide
Blower
Outlet
ASP
CAP
3op?œŸ•‘ “ ’
²±¢p³µ¶·¸¹º»¼½¾¿ÀÁÂ?‘’“”•…†‡denµ´ЗЖЕД´
AIRFLOW CONFIGURATION
Code
Return
Discharge
S
Left
Right
E
Left
Back
Z
Right
Left
B
Right
Back
LEGEND
ASP
— Alternate Service Panel
BSP
— Blower Service Panel
CAP — Control Access Panel
CSP
— Compressor Service Panel
NOTES:
1. Condensate is
3
/
4
-in. FPT copper.
2. Horizontal unit shipped with filter bracket only. This bracket should be removed for return duct connection.
3. Hanger kit is factory installed. Isolation grommets are provided.
4. Right and left orientation is determined by looking at water connection side.
50RHR
UNITS
OVERALL
CABINET
WATER
CONNECTIONS
ELECTRICAL KNOCKOUTS (in.)
DISCHARGE CONNECTION
Duct Flange Installed (±0.10 in.)
RETURN CONNECTION
Using Return Air Opening
1
2
3
Loop
Water
FPT
(in.)
G
1
/
2
conduit
H
1
/
2
conduit
I
3
/
4
conduit
A
Width
B
Depth
C
Height
D
In
E
Out
F
Cond-
ensate
Therm
Ext
Pump
Power
Supply
J
K
L
Supply
Height
M
Supply
Depth
N
O
P
Return
Depth
Q
Return
Height
R
S
006-012
in.
22.4
43.1
11.3
2.4
5.4
0.6
1
/
2
3.5
5.5
8.2
5.8
4.0
5.8
8.0
5.8
1.5
17.1
9.3
2.2
1.0
cm
56.8
109.5
28.7
6.1
13.7
1.5
8.9
14.0
20.8
14.7
10.2
14.7
20.3
14.7
3.8
43.4
23.6
5.6
2.5
015-024
in.
22.4
43.1
17.3
2.4
4.9
0.6
3
/
4
3.5
7.5
10.2
5.0
5.6
10.4
9.3
5.0
1.5
17.1
15.3
2.2
1.0
cm
56.8
109.5
43.9
6.1
12.4
1.5
8.9
19.1
25.9
12.7
14.2
26.4
23.6
12.7
3.8
43.4
38.9
5.6
2.5
030
in.
22.4
53.2
19.3
2.4
5.4
0.6
3
/
4
5.7
9.7
12.2
5.0
6.8
10.4
9.3
5.0
2.1
23.1
17.3
2.2
1.0
cm
56.8
135.1
49.0
6.1
13.7
1.5
14.5
24.6
31.0
12.7
17.3
26.4
23.6
12.7
5.3
58.7
43.9
5.6
2.5
036
in.
22.4
53.2
19.3
2.4
5.4
0.6
3
/
4
5.7
9.7
12.2
2.9
3.8
13.5
13.1
2.9
1.9
23.1
17.3
2.2
1.0
cm
56.8
135.1
49.0
6.1
13.7
1.5
14.5
24.6
31.0
7.4
9.7
34.3
33.3
7.4
4.8
58.7
43.9
5.6
2.5
042-048
in.
22.4
62.2
19.3
2.4
5.4
0.6
1
5.7
9.7
12.2
2.9
3.8
13.5
13.1
2.9
1.9
32.1
17.3
2.2
1.0
cm
56.8
158.0
49.0
6.1
13.7
1.5
14.5
24.6
31.0
7.4
9.7
34.3
33.3
7.4
4.8
81.5
43.9
5.6
2.5
060
in.
25.4
71.2
21.3
2.4
5.4
0.6
1
8.1
11.7
14.2
5.8
5.0
13.6
13.3
5.8
2.9
36.1
19.3
2.2
1.0
cm
64.5
180.8
54.1
6.1
13.7
1.5
20.6
29.7
36.1
14.7
12.7
34.5
33.8
14.7
7.4
91.7
49.0
5.6
2.5
a50-8156