7fig. 2 — 50rhr dimensional data, Left return right return, Unit hanger detail – Carrier AQUAZONE RVC User Manual

Page 7

background image

7

Fig. 2 — 50RHR Dimensional Data

Front

K

M

Blower

Outlet

M

L

Right Return

Front

Left

Discharge

3

CSP

Back

Discharge

Condensate

3/4

“ FTP

3.25

F

Front-View

BSP

Air Coil

C

S

R

B

ASP

Q

P

Front

K

M

Blower

Outlet

J

L

Front

BSP

LEFT RETURN

RIGHT RETURN

Air Coil

CSP

Front

1.1

C

S

Q

P

R

B

Unit Hanger Detail

X

Y

F

ront

Z

Model X Y Z
006-024 43.1 24.375 20.375
030-036 53.1 24.375 20.375
042-048 62.1 24.375 20.375
060 71.1 27.375 23.375

B Configuration - Right Return Back Discharge

ASP

CSP

Front

Left Return

F

3.25

CSP

Condensate

3/4

“ FPT

ASP

3

‘ Service

Access

3

Right

Discharge

Back

Discharge

E Configuration - Left Return Back Discharge

Water
Connection

Water
Connection

2

‘ Service
Access

S Configuration - Left Return Right Discharge -

Air Coil Opening

3

SERVICE

ACCESS

Right

View

Left

View

S Configuration - Left Return Right Discharge -

Air Coil Opening

Z Configuration - Right Return Left Discharge -

Air Coil Opening

Left

View

Right

View

Z Configuration - Right Return Left Discharge -

Air Coil Opening

N

BSP

O

M

C

A

Blower

Outlet

Air Coil

S

ide

L

1/2“

Knockout

Low Voltage

1/2“ Knockout

Power Supply

3/4“ Knockout

A

1.6 [40.6mm]

I

H

G

D

E

1

2

M

N

C

L

O

A

BSP

Air Coil

S

ide

Blower

Outlet

ASP

CAP

3op?œŸ•‘ “ ’

²±¢p³µ¶·¸¹º»¼½¾¿ÀÁÂ?‘’“”•…†‡denµ´ЗЖЕД´

AIRFLOW CONFIGURATION

Code

Return

Discharge

S

Left

Right

E

Left

Back

Z

Right

Left

B

Right

Back

LEGEND

ASP

Alternate Service Panel

BSP

Blower Service Panel

CAP — Control Access Panel
CSP

Compressor Service Panel

NOTES:
1. Condensate is

3

/

4

-in. FPT copper.

2. Horizontal unit shipped with filter bracket only. This bracket should be removed for return duct connection.
3. Hanger kit is factory installed. Isolation grommets are provided.
4. Right and left orientation is determined by looking at water connection side.

50RHR

UNITS

OVERALL

CABINET

WATER

CONNECTIONS

ELECTRICAL KNOCKOUTS (in.)

DISCHARGE CONNECTION

Duct Flange Installed (±0.10 in.)

RETURN CONNECTION

Using Return Air Opening

1

2

3

Loop

Water

FPT
(in.)

G

1

/

2

conduit

H

1

/

2

conduit

I

3

/

4

conduit

A

Width

B

Depth

C

Height

D

In

E

Out

F

Cond-

ensate

Therm

Ext

Pump

Power

Supply

J

K

L

Supply

Height

M

Supply

Depth

N

O

P

Return

Depth

Q

Return

Height

R

S

006-012

in.

22.4

43.1

11.3

2.4

5.4

0.6

1

/

2

3.5

5.5

8.2

5.8

4.0

5.8

8.0

5.8

1.5

17.1

9.3

2.2

1.0

cm

56.8

109.5

28.7

6.1

13.7

1.5

8.9

14.0

20.8

14.7

10.2

14.7

20.3

14.7

3.8

43.4

23.6

5.6

2.5

015-024

in.

22.4

43.1

17.3

2.4

4.9

0.6

3

/

4

3.5

7.5

10.2

5.0

5.6

10.4

9.3

5.0

1.5

17.1

15.3

2.2

1.0

cm

56.8

109.5

43.9

6.1

12.4

1.5

8.9

19.1

25.9

12.7

14.2

26.4

23.6

12.7

3.8

43.4

38.9

5.6

2.5

030

in.

22.4

53.2

19.3

2.4

5.4

0.6

3

/

4

5.7

9.7

12.2

5.0

6.8

10.4

9.3

5.0

2.1

23.1

17.3

2.2

1.0

cm

56.8

135.1

49.0

6.1

13.7

1.5

14.5

24.6

31.0

12.7

17.3

26.4

23.6

12.7

5.3

58.7

43.9

5.6

2.5

036

in.

22.4

53.2

19.3

2.4

5.4

0.6

3

/

4

5.7

9.7

12.2

2.9

3.8

13.5

13.1

2.9

1.9

23.1

17.3

2.2

1.0

cm

56.8

135.1

49.0

6.1

13.7

1.5

14.5

24.6

31.0

7.4

9.7

34.3

33.3

7.4

4.8

58.7

43.9

5.6

2.5

042-048

in.

22.4

62.2

19.3

2.4

5.4

0.6

1

5.7

9.7

12.2

2.9

3.8

13.5

13.1

2.9

1.9

32.1

17.3

2.2

1.0

cm

56.8

158.0

49.0

6.1

13.7

1.5

14.5

24.6

31.0

7.4

9.7

34.3

33.3

7.4

4.8

81.5

43.9

5.6

2.5

060

in.

25.4

71.2

21.3

2.4

5.4

0.6

1

8.1

11.7

14.2

5.8

5.0

13.6

13.3

5.8

2.9

36.1

19.3

2.2

1.0

cm

64.5

180.8

54.1

6.1

13.7

1.5

20.6

29.7

36.1

14.7

12.7

34.5

33.8

14.7

7.4

91.7

49.0

5.6

2.5

a50-8156

This manual is related to the following products: