Form RZ-NA-I-FE/BE, Mfg P/N 98807, Rev 10, Page 22
30. Optional Guards -
Options CD10 & CD12
(Blower Models only)
These guard options are designed to provide complete pro-
tection from the rotating drive and/or blower components.
Option CD12 is designed for use with Sizes 25-100 with
standard direct drive motor. This kit includes only the blower
inlet guard.
Option CD10 is designed for use on Sizes 50-400 with a
belt driven motor and includes both the belt guard and the
blower inlet guard.
Figure 22 - Optional Guards
Optional
Belt
Guard
Installed
Optional Blower Inlet
Guard Installed
Figure 21 - Polytube Adapter
The polytube adapter option package does not include
polytubing. Polytubing can be obtained from a supply dis-
tributor such as FOF Products, Inc., P. O. Box E, 1505
Racine Street, Delevan, WI 53115; ACME Engineering Co.,
P.O. Box 978, Muskogee, OK 74402; or any local green-
house supply distributor. Some local code authorities re-
quire the polytube material to be a listed material. Consult
code authority having jurisdiction and the polytube sup-
plier to determine the appropriate polytube material and
recommended methods of suspension.
The following chart shows specification information covering the use of polytubes with these blower-type unit heaters.
Illustration shows Option
CD8, Polytube Adapter for
Floor-Mounted Heater.
Options CD6 and CD11
are for Suspended Heaters.
Conversion Table
(Diameter to Area)
Diameter
Area of
of the Hole
the Hole
(inches)
(sq in)
2-1/2
4.91
2-1/4
3.98
2
3.14
1-7/8
2.76
1-1/2
1.76
1
0.785
CFM at Poly tube M inimum Free
Sugges ted Hole Sizes and Locations
Size
.25" Diameter Area
(square
Length of Polytube
ESP
(inches)
Inches)
50 Ft
75 Ft
100 Ft
125 Ft
150 Ft
Number
37p airs
75 p airs
75 p airs
75
925
18
110
Diamet er
1-1/2"
1"
1"
Sp acing
16"
12"
16"
Number
50 p airs 50 p airs 100 p airs
94 p airs
100
1235
18
145
Diamet er
1-1/2"
1-1/2"
1"
1"
Sp acing
12"
18"
12"
16"
Number
40 p airs 60 p airs
60 p airs
125 p airs
125
1540
18
185
Diamet er
1-7/8"
1-1/2"
1-1/2"
1"
Sp acing
15"
15"
20"
12"
Number
40 p airs 60 p airs
60 p airs
125 p airs
130
1600
24
190
Diamet er
1-7/8"
1-1/2"
1-1/2"
1"
Sp acing
15"
15"
20"
12"
Number
50 p airs 50 p airs
75 p airs
75 p airs
75 p airs
165
2035
24
240
Diamet er
1-7/8"
1-7/8"
1-1/2"
1-1/2"
1-1/2"
Sp acing
12"
18"
16"
20"
24"
Number
42 p airs 42 p airs
60 p airs
60 p airs
100 p airs
200
2465
24
300
Diamet er
2-1/4"
2-1/4"
1-7/8"
1-7/8"
1-1/2"
Sp acing
14"
21"
20"
25"
18"
Number
40 p airs 60 p airs
60 p airs
60 p airs
60 p airs
250
3085
24
360
Diamet er
2-1/2"
2"
2"
2"
2"
Sp acing
15"
15"
20"
25"
30"
Number
75 p airs 75 p airs
75 p airs
75 p airs
75 p airs
300
3700
24
425
Diamet er
2"
2"
2"
2"
2"
Sp acing
9"
12"
16"
20"
24"
Number
60 p airs 60 p airs
60 p airs
100 p airs 100 p airs
400
4935
24
550
Diamet er
2-1/2"
2-1/2"
2-1/2"
1-7/8"
1-7/8"
Sp acing
10"
15"
20"
15"
18"
Holes
29. Optional Polytube Adapter - Options CD6, CD8, and CD11 (Blower
Models only) (cont'd)