Form RZ-NA-I-FE/BE, Mfg P/N 98807, Rev 10, Page 22

30. Optional Guards -

Options CD10 & CD12
(Blower Models only)

These guard options are designed to provide complete pro-
tection from the rotating drive and/or blower components.
Option CD12 is designed for use with Sizes 25-100 with
standard direct drive motor. This kit includes only the blower
inlet guard.

Option CD10 is designed for use on Sizes 50-400 with a
belt driven motor and includes both the belt guard and the
blower inlet guard.

Figure 22 - Optional Guards

Optional
Belt
Guard
Installed

Optional Blower Inlet

Guard Installed

Figure 21 - Polytube Adapter

The polytube adapter option package does not include
polytubing. Polytubing can be obtained from a supply dis-
tributor such as FOF Products, Inc., P. O. Box E, 1505
Racine Street, Delevan, WI 53115; ACME Engineering Co.,
P.O. Box 978, Muskogee, OK 74402; or any local green-
house supply distributor. Some local code authorities re-
quire the polytube material to be a listed material. Consult
code authority having jurisdiction and the polytube sup-
plier to determine the appropriate polytube material and
recommended methods of suspension.

The following chart shows specification information covering the use of polytubes with these blower-type unit heaters.

Illustration shows Option
CD8, Polytube Adapter for
Floor-Mounted Heater.
Options CD6 and CD11
are for Suspended Heaters.

Conversion Table
(Diameter to Area)

Diameter

Area of

of the Hole

the Hole

(inches)

(sq in)

2-1/2

4.91

2-1/4

3.98

2

3.14

1-7/8

2.76

1-1/2

1.76

1

0.785

CFM at Poly tube M inimum Free

Sugges ted Hole Sizes and Locations

Size

.25" Diameter Area

(square

Length of Polytube

ESP

(inches)

Inches)

50 Ft

75 Ft

100 Ft

125 Ft

150 Ft

Number

37p airs

75 p airs

75 p airs

75

925

18

110

Diamet er

1-1/2"

1"

1"

Sp acing

16"

12"

16"

Number

50 p airs 50 p airs 100 p airs

94 p airs

100

1235

18

145

Diamet er

1-1/2"

1-1/2"

1"

1"

Sp acing

12"

18"

12"

16"

Number

40 p airs 60 p airs

60 p airs

125 p airs

125

1540

18

185

Diamet er

1-7/8"

1-1/2"

1-1/2"

1"

Sp acing

15"

15"

20"

12"

Number

40 p airs 60 p airs

60 p airs

125 p airs

130

1600

24

190

Diamet er

1-7/8"

1-1/2"

1-1/2"

1"

Sp acing

15"

15"

20"

12"

Number

50 p airs 50 p airs

75 p airs

75 p airs

75 p airs

165

2035

24

240

Diamet er

1-7/8"

1-7/8"

1-1/2"

1-1/2"

1-1/2"

Sp acing

12"

18"

16"

20"

24"

Number

42 p airs 42 p airs

60 p airs

60 p airs

100 p airs

200

2465

24

300

Diamet er

2-1/4"

2-1/4"

1-7/8"

1-7/8"

1-1/2"

Sp acing

14"

21"

20"

25"

18"

Number

40 p airs 60 p airs

60 p airs

60 p airs

60 p airs

250

3085

24

360

Diamet er

2-1/2"

2"

2"

2"

2"

Sp acing

15"

15"

20"

25"

30"

Number

75 p airs 75 p airs

75 p airs

75 p airs

75 p airs

300

3700

24

425

Diamet er

2"

2"

2"

2"

2"

Sp acing

9"

12"

16"

20"

24"

Number

60 p airs 60 p airs

60 p airs

100 p airs 100 p airs

400

4935

24

550

Diamet er

2-1/2"

2-1/2"

2-1/2"

1-7/8"

1-7/8"

Sp acing

10"

15"

20"

15"

18"

Holes

29. Optional Polytube Adapter - Options CD6, CD8, and CD11 (Blower

Models only) (cont'd)