Reznor XE Unit Installation Manual User Manual

Page 6

background image

Form I-XE/CRGB/RPB, P/N 131782 Rev 5, Page 5

86-11/16 (2202)

Blower

Cabinet

Furnace

Airflow

Field Control

Wiring

Entrance

39-3/16*

(995)

Optional Downturn Plenum Cabinet

A

38-1/8**

(968)

Field Wiring

(line voltage)

Gas

Curb Cap

C

B

38-5/8 (981)

4-3/32

(104)

19-1/2

(495)

19-1/2

(495)

85-13/16 (2180)

Optional

Return

Air Inlet

Vertical

Discharge

1-1/32

(26)

4-1/4

(108)

4-1/4

(108)

Left Side View with Vertical Discharge

Front View with

Opt ional Vertical Discharge

(Downturn Plenum Option AQ5 or AQ8)

4-3/32

(104)

5 (127)

19-1/2

(495)

4-5/8

(117)

31-11/32

(796)

43-17/32 (1106)

Screened

Outside

Air Hood -

Option AS2

5 (127)

19-1/2

(495)

Blower

Cabinet

1-1/32 (26)

61-3/8 (1559)

Control Wiring

Entrance

Furnace

Airflow

Curb Cap

Gas

Field Wiring

(line voltage)

61-7/8 (1572)

A

38-1/8**

(968)

3/4(19)

3/4(19)

D

B

C

Left Side View with Horizontal Discharge

Front View with

Standard Horizontal Discharge

3/4(19)

3/4(19)

39-3/16*

(995)

18

(457)

11-1/4(286)

8-1/2(215)

FIGURE 1C -
Dimensions, Outdoor/
Power-Vented Model
Series RPB

NOTES:

*Height from top of
cabinet to top of curb
cap.

**Height from top of
cabinet to bottom of
cabinet side.

*** If system has a cooling
coil cabinet, add length
dimension on page 6 for full
system length.

**** The two-position
discharge dampers in
Option AQ8 fit in the
discharge air opening. The
damper motor fits inside
the downturn plenum
cabinet. For dimensions
with downturn plenum
cabinet with a cooling coil
cabinet, see page 6.

Gas Connection

Natural

Propane

inches

28-5/8

17-3/8

25-7/8

15-1/4

1/2

1/2

mm

727

441

657

387

13

13

inches

34-1/8

22-7/8

31-3/8

20-3/4

1/2

1/2

mm

867

581

797

527

13

13

inches

39-5/8

28-3/8

36-7/8

26-1/4

1/2

1/2

mm

1006

721

937

667

13

13

inches

47-7/8

36-5/8

45-1/8

34-1/2

1/2

1/2

mm

1216

930

1146

876

13

13

inches

47-7/8

36-5/8

45-1/8

34-1/2

3/4

1/2

mm

1216

930

1146

876

19

13

inches

53-3/8

42-1/8

50-5/8

40

3/4

1/2

mm

1362

1070

1286

1016

19

13

inches

58-7/8

47-5/8

56-1/8

45-1/2

3/4

1/2

mm

1470

1210

1426

1156

19

13

Air Openings:

Dimensions

Standard Horizontal Air Inlet

19-1/2 (495) x B

Optional Return Air Opening (bottom)

19-1/2 (495) x B

Standard Horizontal Discharge Air Opening

18 (457) x D

19-1/2 (495) x B

****for downturn plenum with cooling coil cabinet, see page 6.

C

D

Model S ize

A

B

Optional Vertical Discharge Air Opening (with Option AQ5 or AQ8
Downturn Plenum****)

300

350

400

(H)-RPB

125

150, 175

200, 225

250