Technical specifications 1.0, Danger – Proheat M80 User Manual
Page 14

SYSTEM INPUTS
SWITCH
10 – 30V
Standard Run Mode
Preheat Run Mode
Supplemental Run Mode
COOLANT PUMP
10 – 30V
AUXILIARY
Allows independent operation of Coolant Pump through
the Proheat Control Module
POWER
12 Volt or 24 Volt
M50 12V
M50 24V
M80 12V
M80 24V
RATING BTU/hr (kW)
50,000 (15)
50,000 (15)
80,000 (23)
80,000 (23)
SYSTEM VOLTAGE
Nominal DC Voltage (Range)
12 (10 – 15)
24 (20 – 30)
12 (10 – 15)
24 (20 – 30)
CURRENT DRAW (MAX) Amps
9.5
5.2
8.5
5.2
FUEL CONSUMPTION US gal/hr (L/hr)
0.48 (1.8)
0.48 (1.8)
0.78 (2.95)
0.78 (2.95)
IGNITION TYPE
Electronic Spark Ignition
COOLANT OUTPUT TEMPERATURE MAX.
185°F (85°C)
AMBIENT OPERATING TEMPERATURE
-40°F to +122°F (-40°C to +50°C)
WEIGHT lbs (kg)
53 (24)
HEAT EXCHANGER CAPACITY US gal (l)
0.5 (2)
COOLANT SYSTEM
Minimum Capacity US gal (l)
2.64 (10)
2.64 (10)
2.64 (10)
2.64 (10)
Recommended Flow Rate Through
Heater US gpm (lpm)
5 (19)
5 (19)
7 (26.5)
7 (26.5)
PROHEAT G-I PCM SERVICE MANUAL
1-1
TECHNICAL
SPECIFICATIONS
1.0
SYSTEM OUTPUTS
AUXILIARY OUTPUT
Same as System Voltage
Maximum 1 Amp draw (over-load shut-off protection)
High-side switched
SWITCH/TIMER
Same as System Voltage
POWER
Maximum 1 Amp draw (over-load shut-off protection)
High-side switched
COOLANT PUMP
Same as System Voltage
Maximum 10 Amp draw (over-load shut-off protection)
High-side switched
INDICATOR LIGHT
Same as System Voltage
Maximum 1 Amp draw (over-load shut-off protection)
High-side switched
DANGER
Do not use gasoline.
FUEL TYPES
COMPATIBLE
Diesel (ULSD, #1, #2, Arctic), JP8, Jet A1
Bio Fuels - Contact Proheat www.proheat.com