Comm led operation, Bypassing calibration, Green – PRG Bad Boy User Manual 1.6 User Manual
Page 34: If no dmx or ethernet is present

26
BAD BOY
®
SPOT LUMINAIRE USER MANUAL
Comm LED Operation
The Comm LED - located on the upper enclosure connector panel - indicates system control status. This can be used
determine if the luminaire is receiving a control signal. LED indications are as follows:
Figure 2-12: Comm LED
+
Green - The Comm LED will light
green
if either DMX or Ethernet control is present. Note that if both valid DMX
and Ethernet control are being received, DMX control will take precedence.
+
Red - The Comm LED will light
red
if no DMX or Ethernet is present.
Bypassing Calibration
If the menu screen is touched (in the center) and held during startup, the luminaire will
present a menu that provides the option to bypass calibration. This feature allows the
luminaire to skip the calibration sequence so that it can be powered up in the case for
configuration purposes.
To bypass calibration:
Step
1. Connect power to luminaire.
Step
2. At startup, touch center of menu screen and hold until Bypass Calibration
menu appears.
Step
3. Press
Yes
to bypass calibration. (The menu will automatically dismiss if no
selection is made within 5 seconds.)
Step
4. Proceed with programming of starting address or other options.
CONFIG
addr
043
univ
A
1400w
ETHERNET
COMM
IN
DMX
THRU
15A Max
AC IN
200 -240 VAC
50 / 60 Hz
LAMP
hrs
125
temp
34C
INFO
01:34
TEST
COMM
DMX
STATUS
OK
IS POW ERED
ACTIVE ON LY
WHEN FIXTURE
Comm LED