39

Performance

Data Sheet

Culligan Platinum

Plus Series 14” Water

Softener with Soft-

Minder

®

Meter

Culligan knows the more informed you are about your water treatment systems, the more confident you will be

about its performance. It’s because of this and seventy years of commitment to customer satisfaction that Culligan

is providing this Performance Data Sheet to its customers.
Important Notice: Read this Performance Data Sheet and compare the capabilities of this unit with your

actual water treatment needs. It is recommended that before purchasing a water treatment unit, you have your

water supply tested to determine your actual water treatment needs.

MANUFACTURER: Culligan International Company

9399 West Higgins Road, Suite 1100, Rosemont, IL 60018 USA

(847) 430-2800

PRODUCT:

Culligan Platinum Plus Series 14” Water Softener with Soft-Minder

®

Meter

TESTING CONDITIONS & RESULTS:
Flow Rate:
20.5 gpm @ 15 psi

Capacity: 56,420 grains @ 12.0 lb. salt

Pressure: 30 - 40 psi

76,520 grains @ 24.0 lb. salt

Acidity: Non-Corrosive

90,676 grains @ 36.0 lb. salt

Temperature: 68° (20°C)

pH: 7.6

Efficiency Rated Dosage†: 4,702 gr/lb

SOFTENER SPECIFICATIONS:

Max. Flow Rate: 20.5 gpm (77.6 Lpm)

Pressure Drop at Max. Flow Rate: 15 psi (105 kPa)

Operating Temp. Range: 33-125°F (1-50°C)

Max. Drain Flow Rate: 5.0 gpm (19.0 Lpm)

Working Pressure Range: 20-120 psi (140-860 kPa)

Operating Pressure Range (Canada): 20 - 90 psi (140 - 620 kPa)

Name of

Substance

USEPA Max.

Contaminant Level

pH

Flow Rate

Pressure

Barium

2.0 mg/L

7.5 + 0.5

31.2 gpm

35 + 5 (psig)

Radium 226/228

5pCi/L

7.5 + 0.5

31.2 gpm

35 + 5 (psig)

This system is certified for barium and radium 226/228 reduction based on hardness reduction. It is recommended you test your

water every 6 months to ensure the system is performing properly and that hardness, and therefore barium and radium 226/228,

are being reduced. Hardness test strips have been included. Additional strips are available from your local Culligan dealer.
The Culligan Platinum Plus Series 14” Water Softeners with Soft-Minder

®

Meter are tested and certified by WQA against NSF/

ANSI Standard 44 for the effective reduction of hardness (calcium and magnesium) and barium/radium 226/228 as verified and

substantiated by test data.
An efficiency rated water softener is a DIR softener which also complies with specific performance specifications intended to

minimize the amount of regenerant brine and water used in its operation. Efficiency rated water softeners shall have a rated salt

efficiency of not less than 3350 grains of total hardness exchange per pound of salt (based on NaCl equivalency) (477 grams

of total hardness exchange per kilogram of salt), and shall not deliver more salt than its listed rating. The efficiency is measured

by a laboratory test described in NSF/ANSI 44. The test represents the maximum possible efficiency the system can achieve.

Operational efficiency is the actual efficiency achieved after the system has been installed. It is typically less than the efficiency due

to individual application factors including water hardness, water usage, and other contaminants that reduce the softener’s capacity.
Refer to the Specifications, Familiarization and Warranty section of this Owner’s Guide for more specific product information. To

avoid contamination from improper handling and installation, your system should only be installed and serviced by your Culligan

Man. Performance will vary based on local water conditions. The substances reduced by this system are not necessarily in your water.
Culligan water softeners are designed to work with any salt of good quality, although it is recommended that you ask your local

Culligan Man for his suggestion on the best type and grade of salt to use in this softener.
Notice: This softener is not intended to be used for treating water that is microbiologically unsafe or of unknown quality without

adequate disinfection before or after the system.
† The efficiency rated dosage is only valid at the 12lb. salt dosage and maximum service rate for 14” models, and is efficiency

rated according to NSF/ANSI 44.