Programming (cont.) – Culligan Platinum Plus Series User Manual

Page 24

background image

20

Programming

(cont.)

• Regeneration Interval - This setting is used to set

the days between regeneration in time clock mode. It

is also active in meter or Aqua-Sensor

®

mode if the

time clock backup DIP switch # 10 is set to on. The

display will show “REGEN” icon and “dAYS” as well

as the numbers to change. Adjust the value with the

“Up” or “Down” keys.

Pressing the “Program” key will save the setting and move to the next programming step.

• Hardness Setting - This setting is used to set the

hardness (grains) of the influent water supply. For

English Units the display will first show “Hard” for two

seconds and then display the Hardness default (or the

previously programmed value). Adjust the value with

the “Up” or “Down” keys.

(These settings will not get saved to EEPROM until the

‘Program’ key is pressed while at the ‘View’ programming step)

• Iron Setting (flow meter only) - This setting is

used to set the iron level of the influent water supply.

The display will show “Iron” in the left most digits and

the iron default setting (or the previously programmed

value) in the far right digit. The display will only

appear if a flow meter is connected to the circuit

board. If the iron level is set to “Y”, the Efficiency

Mode is inactive. Adjust the value with the “Up” or “Down” keys.

Pressing the “Program” key will temporarily store the setting and move to the next

programming step. (This setting will not get saved to EEPROM until the ‘Program’ key is

pressed while at the ‘View’ programming step)

• Pressure Setting - This setting is used to set the

influent water pressure. The display will show “LowP”

in the left most digits and the pressure default setting

in the far right digit. If the pressure is less than 40

psi, chose “Y”. By choosing “Y” the brine rinse time

will be extended. Adjust the value with the “Up” or

“Down” keys.

Pressing the “Program” key will temporarily store the setting and move to the next

programming step.

• Salt Type (flow meter only) - This setting is used to select the regeneration salt type

(softener mode only). This display will only appear if dip # 4 is off. The display will show

“SALt” for 2 seconds. Then display the default ‘NACL’. Pushing the “Up” or “Down” keys

will change to ‘KCL’.

Pressing the “Program” key will temporarily store the setting and move to the next

programming step. (This setting will not get saved to EEPROM until the ‘program’ key is

pressed while at the ‘View’ programming step)