Final Start-Up

Regeneration

There are several conditions that will cause the control to trip a regeneration. The “REGEN”

enunciator will light when the control has signaled for a regeneration. The “REGEN” enunciator

will flash while the control is in regeneration. The following are conditions that will call for

regeneration:

1 When the Soft-Minder

®

meter has recorded the passage of a predetermined number of

gallons.

2 When the Aqua-Sensor

®

Probe senses the hardness in the Cullex Media.

3 At the preset time, when the number of days without a regeneration is equal to the Timeclock

Backup setting.

4 At the preset time, when the “REGEN” button is depressed once. “REGEN” will light.
5 Immediately, when the “REGEN” button is depressed for three seconds. “REGEN” will light

and blink.

6 Immediately, if power to the unit has been off for more than 3 hours and time of day has

been restored.