31

Care and

Cleaning of

your Water

Conditioner

(cont.)

Sanitizing Procedure

A water softener in daily use on a potable water supply generally requires no special attention

other than keeping the salt tank filled. Occasionally, however, a unit may require sanitization

under one of the following conditions:
• At start-up time.
• After standing idle for a week or more.
• On private supplies, the appearance of off-tastes and odors, particularly if musty or “rotten

egg” (caused by harmless sulfate-reducing bacteria).

1. Remove the brine tank cover.
2. Pour directly into the brine chamber 1/3 to 1/2 cup of common household bleach (5.25%

sodium hypochlorite) for each cubic foot of resin in the tank.

3. Manually start recharge. Allow the unit to complete the recharge cycle automatically.

If tastes and odors return frequently, even after sanitization, a continuous chlorination system may

be needed. Send a water sample to a qualified laboratory for bacterial analysis.

Caution! Hazard from toxic fumes! Chlorine bleach and common iron control

chemicals may generate toxic fumes when mixed.

• If the unit uses Culligan Sofner-gard

®

or other compounds containing sodium

hydrosulfite, sodium bisulfite, or any other reducing agent, disconnect the

device feeding the chemical(s) and manually regenerate the unit before

sanitizing.

• Do not use this procedure if the softener salt contains iron control additives.

Note: If the water supply contains iron, regenerate the softener before sanitizing to

remove iron from the resin.