10

Installation

With the exception of media containers, open the remaining containers, remove all the

components, and inspect them before starting installation.

Placement

Refer to figure 1 for system placement.
• Set the media tank on a solid, level surface near water, drain and electrical facilities.
• Set the brine system on a flat, smooth, solid surface as near the media tank as possible.

Tank Assembly

Before the unit can be connected to the plumbing the manifold distributors must be assembled

and the underbedding and resin must be loaded into the tank for 12”, 14” and 16” tanks.

Position of the Mineral Tank(s)

Determine the location for the mineral tanks(s) prior to loading, since they will be difficult to move

after the underbedding and gravel are loaded.

Caution! DO NOT lay the tank down unless a suitable lifting device is available.

Personal injury and damage to the unit can result if dropped.

Note: Read this section entirely before starting the installation. Follow all applicable

plumbing and electrical codes.

Drain Line

Hard Water In

Heater

Treated Water Out

To

Hose

Bibs

Water

Meter

or

Pump

Air Gap

Softener

Brine Tank

Figure 1