Programming

(cont.)

The Culligan

®

AccuSoft

®

Plus circuit board controls all the softener functions. These settings are

programmed at the time of installation. The following is a list of all the microprocessor functions

in the event that any of the settings need to be adjusted.
A further description of each programming setting and the corresponding display is outlined

below. For a display that has an icon that is displayed solid for the 2 second time period prior

to bringing up the settings, the settings menu can be reached prior to the two second time out by

pressing the “Up” or “Down” key.

• Beeper Setting - This setting is used to turn the

beeper on or off for each key press actuation. The

display will show “bEEP X” where X is either “Y” or

“N”. The “Y” or “N” will be toggled with the “Up”

and “Down” keys. Setting the Beep option to “N”

will only disable the beeper for key press actuation.

The beeper will still be active for error and alarm

codes.

Pressing the “Program” key will save the setting and move to the next programming step.

• Time of Day - This setting is used to program the

current time of day. When in this step the display will

first show “tod” for two seconds.

After “tod” is displayed, “12:00 PM” will display

(or the current set time if already programmed) and

the minutes will flash. The minutes are adjusted with

the “Up” or “Down” key until the correct value is

displayed.

Press the “Regen” key to flash the hours. Adjust with the “Up” or “Down” key until the

correct time is displayed.

Pressing the “Program” key will save setting and move to the next programming step.

Pressing “Regen” will move back to the minutes adjust.

• Time of Regeneration - This setting is used to

program the time at which a regeneration is to occur

in the delay mode, or in immediate mode with time

clock backup on. The display will first show “tor” for

two seconds.

After “tor” is shown the display will then show the

default of 2:00 AM (or the current programmed

time of regeneration if already set). The time can

be adjusted in 30 minute increments by pressing the

“Up” or “Down” keys.

Pressing the “Program” key will save the setting and

move to the next programming step.

Hours Flashing

Minutes Flashing

Time Flashing