Installation

(cont.)

Drain Line Connection

Refer to Table 3, for drain line length and height limitations.

• Remove 1/2” pipe clamp from the small parts pack included with the control.
• Route a length of 1/2” drain line from the drain elbow to the drain.
• Fasten the drain line to the elbow with the clamp.
• Secure the drain line to prevent its movement during regeneration. When discharging into a

sink, or open floor drain, a loop in the end of the tube will keep it filled with water and will

reduce splashing at the beginning of each regeneration.

Height of Discharge Above Floor Level Operating

Operating

Pressure

0 ft (0 m)

2 ft

(0.6 m)

4 ft

(1.2 m)

6 ft

(1.8 m)

8 ft

(2.4 m)

10 ft

(3 m)

30 psi

(210 kPa)

60 ft

(18 m)

50 ft

(15 m)

30 ft (9 m)

15 ft (5 m)

Not

allowable

Not

allowable

40 psi

(279 kPa)

100 ft

(30 m)

90 ft

(27 m)

70 ft

(21 m)

50 ft

(15 m)

30 ft (9 m)

12 ft (4 m)

50 psi

(349 kPa)

145 ft

(41 m)

115 ft

(35 m)

80 ft

(24 m)

80 ft

(24 m)

60 ft

(18 m)

40 ft

(12 m)

60 psi

(419 kPa)

100 ft

(30 m)

100 ft

(30 m)

85 ft

(26 m)

60 ft

(18 m)

80 psi

(559 kPa)

Normal installation should not require

more than 100 ft (30 m) of drain line

140 ft

(43 m)

120 ft

(37 m)

100 psi

(699 kPa)

150 ft

(46 m)

Table 3 - Maximum Allowable Drainline Length

Fill the Storage Container

Fill the salt storage container with water until the level reaches about 1 inch above the salt

support plate. Pour salt into the container. Fill with salt to within a few inches of the top.

Note: Waste connections or drain outlets shall be designed and constructed to provide

for connection to the sanitary waste system through an air gap of 2 pipe diameters or 1

inch, whichever is larger.
Note: Observe all plumbing codes. Most codes require an anti-siphon device or air gap

at the discharge point. The system and installation must comply with state and local laws

and regulations. For installations in Massachusetts, Massachusetts Plumbing

Code 248 CMR shall be adhered to. Consult your licensed plumber for

installation of this system. This system and its installation must comply with

state and local regulations.