33

Error Codes

The Accusoft Plus microprocessor is equipped with an advanced error detection system. During

all operating modes the softener’s electronics are performing self-diagnostics to ensure that the

unit is operating correctly. There may be times, however, when something may occur that could

cause the unit to improperly operate. In those instances the microprocessor will identify the exact

problem and alert the user with an error code. Shown below is a description of the error codes.

Beeping only occurs between the hours of 8:00 am and 8:00 pm. Beeping can be silenced by

pressing any key.
To reset an error, press and hold for 10 seconds the ‘Program’ button. The unit will beep and

check to see if indeed the error has been fixed. If the error was not fixed, the board will re-

display the error code. If the error code does not reset please contact your local Culligan Dealer.

For additional troubleshooting or service needs, please contact your local Culligan Dealer.

Display

Alert Code

Description

Mode of Detection

Comments

ERR 1

Motor Failure to

Start

If the valve fails to reach the

desired state within 70 seconds

of driving the motor. The control

will attempt to start the motor 3

times for 70 seconds each time

with a 60 second off period

between each attempt.

Press and hold ‘Program’

key for 10 seconds.

ERR 2

Motor Failure to

Stop

If the control detects changes in

the Cam inputs when the motor

is not supposed to be turning.

Press and hold ‘Program’

key for 10 seconds.

ERR 3

Incorrect Cycle

Position

The control expects to be in

a different position than that

indicated by the Cam switch

closures.

Press and hold ‘Program’

key for 10 seconds.

ERR 4

Control type does

not match.

-If dips# 3 & 4 are set and 5-

cycle valve is not detected.

Press and hold ‘Program’

key for 10 seconds.

CHECK
SALT

A/S mode;

control detected

no brine during

brine rinse cycle.

A very distinct signal is expected

from the probe during brine

rinse; lack of this signal means

no brine was detected.

Once this alert is

triggered, the A/S is

no longer a valid regen

trigger. The alert can

only be cleared after a

successful regeneration

of the resin bed.