beautypg.com

Wn in, Figure 5-20 – Cabletron Systems 6000 User Manual

Page 100

background image

Chapter 5: Local Management

5-54

6E128-26, 6E138-25, 6E129-26 and 6E139-25 User’s Guide

Figure 5-20

COM Port Warning Screen

3.

Use the arrow keys to highlight YES. Press ENTER.

4.

If you the port was enabled, proceed to

Section 5.15.12

. If the port was

disabled, use the arrow keys to highlight SAVE at the bottom of the
screen, then press ENTER. When the message “SAVED OK”
displays, the edits are saved.

NOTE

If the 6C105 chassis has been configured with a valid IP
address this screen will not appear. When the chassis is
assigned a valid IP address all the interface modules installed
share this same address.

!

CAUTION

Exiting without saving causes the message “NOT SAVED --
PRESS SAVE TO KEEP CHANGES” to appear. Exiting without
saving causes all edits to be lost.

WARNING

174252

THE COM PORT HAS BEEN RECONFIGURED AND THERE IS NO IP

ADDRESS SET FOR THIS DEVICE. YOU WILL NO LONGER BE ABLE

TO MANAGE THIS BOARD. DO YOU STILL WISH TO RECONFIGURE

THIS COM PORT?

YES

NO