DIO5 Reference Manual

Digilent, Inc.

www.digilentinc.com

Page

6

Copyright Digilent, Inc. All rights reserved. Other product and company names mentioned may be trademarks of their respective owners.

LCD Read Cycle

tsu

th

th

tw

tr

tf

tD

tDH

tc

R/W

RS

E

DB0-DB7


LCD Write Cycle

tsu

th

th

tw

tr

tf

tsu1

th1

tc

R/W

RS

E

DB0-DB7





























Table 5. LCD Bus Timings

Parameter Symbol

Min

Max

Unit

Test

Pin

Enable cycle time

tc

500

ns

E

Enable High pulse width

tw

220

ns

E

Enable rise/fall time

tr, tf

25

ns

E

RS, R/W setup time

tsu

40

ns

RS, R/W

RS, R/W hold time

th

10

ns

RS, R/W

Read data output delay

tD

60

120

ns

DB0-DB7

Read data hold time

tDH

20

ns

DB0-DB7

Write data setup time

tsu1

40

ns

DB0-DB7

Write data hold time

th1

10

ns

DB0-DB7

Wait for 20ms

Power On

Function Set

Wait for 37us

Display Control Set

Wait for 37us

Display Clear

Wait for 1.52ms

OK for operations

LCD startup sequence