Verify power supply alarm configuration – Cisco XM Universal Gateways Cisco AS5400XM User Manual
Page 87
B-21
Cisco AS5400XM Universal Gateway Chassis Installation Guide
OL-6418-02
Appendix B Replacing the Power Supply
Configuring the Power Supply Alarm
Verify Power Supply Alarm Configuration
To verify the status of the power supply alarm configuration, enter the show facility-alarm command:
5400# show facility-alarm
Device State
------ -----
GigabitEthernet0/0 UP
Modem Card 4 UP
Facility Alarm is ON
Note
For information on connecting alarm devices to the alarm port on the Cisco AS5400XM
universal gateway, see the
“Connecting to the Alarm Port” section on page 3-11
Step
Command
Purpose
Step 1
Router> enable
Password: password
Router#
Enters enable mode. Enter the password.
You have entered enable mode when the prompt changes to
Router#
.
Step 2
Router# configure terminal
Enters global configuration mode.
Step 3
Router(config)# facility-alarm detect rps
Turns on an alarm when a redundant power supply failure is
detected. Any of the following failures will turn on the alarm:
•
Input power voltage failure
•
Output power voltage failure
•
Overvoltage condition
•
Multiple failures