Setting the chassis on a desktop – Cisco XM Universal Gateways Cisco AS5400XM User Manual
Page 32
3-2
Cisco AS5400XM Universal Gateway Chassis Installation Guide
OL-6418-02
Chapter 3 Installing the Cisco AS5400XM Universal Gateway
Setting Up the Chassis
Warning
When installing or replacing the unit, the ground connection must always be made first and
disconnected last. Statement 1046
Warning
This unit is intended for installation in restricted access areas. A restricted access area can be
accessed only through the use of a special tool, lock and key, or other means of security.
Statement 1017
Setting the Chassis on a Desktop
The location of the chassis is extremely important for proper operation. Equipment placed too close
together, inadequate ventilation, and inaccessible panels can cause malfunctions and shutdowns, and can
make maintenance difficult. The following information will help you to plan the location of the chassis:
•
Plan for access to both front and rear panels of the chassis.
•
Ensure that the room where the chassis operates has adequate ventilation. Remember that electrical
equipment generates heat. Ambient air temperature may not cool equipment to acceptable operating
temperatures without adequate ventilation.
Attach the rubber feet as shown in
. Rubber feet are included in the accessory kit that shipped
with your Cisco AS5400XM universal gateway.
Figure 3-1
Attaching the Rubber Feet
37208
Universal gateway
chassis bottom