Secure menu, Appendix d – AERCO KC1000 Heater w/Mod-Box Controller User Manual
Page 68

APPENDIX D
x
bp 7
bp_8
BREAK POINT 8
85
bp 8
bp_9
BREAK POINT 9
81
bp 9
bp_A BREAK
POINT
79
bp A
bp_B BREAK
POINT
77
bp B
SECURE MENU
SECr
SECURITY LEVEL
3
Func
MODE OF OPERATION
fDfO
gAin GAIN
.05
Pb3 PROPORTIONAL
BAND
5000
Lofi LOW
FIRE
29
LFti
LOW FIRE TIMER
0
Purg
PURGE
100
O2-O STOP
LEVEL
16%
O2-C START
LEVEL
20%
FLti
FAULT TIMER
0SEC.
dFil DISPLAY
FILTER
2
ArUP
ANTI RESET WINDUP
ON
PEA
PEAK(Highest Temp. Unit Has Seen Since Reset)
ACTUAL
VAL
VALLEY(Lowest Temp. Has Seen Since Reset)
ACTUAL
bp
BREAK POINTS ON or OFF
OFF
InPC INPUT
CORRECTION
0
InPt INPUT
TIMER
OFF
FiLt SENSOR
FILTER
4
Unit
UNIT OF DISPLAY
F
Addr ADDRESS
32
bAUd BAUD
RATE
9600
InP INPUT
CAL
See also other documents in the category AERCO Equipment:
- AERClean (12 pages)
- ProtoNode Gateway Rev 1 (with internal LEDs) (64 pages)
- ProtoNode Gateway Rev 3 (with external LEDs) (126 pages)
- Control System (ACS) (144 pages)
- Belimo F6...HD/HDU Series Valve (44 pages)
- Belimo AF120-S US Actuator (9 pages)
- Belimo AMX24-MFT Actuator (9 pages)
- Belimo GKX24-MFT Actuator (9 pages)
- Belimo Motorized Valves Installation (20 pages)
- BMS II BOILER (108 pages)
- BMS II BOILER MODBUS Communication (100 pages)
- BMS 168 (86 pages)
- Boiler Valve Controller (BVC) PRIOR to Serial-12-840-1 (35 pages)
- Boiler Valve Controller (BVC) (38 pages)
- Buffer Tanks (14 pages)
- Combination Control Panel (CCP) (4 pages)
- XPC GATEWAY Communications (193 pages)
- Domestic Water Storage Tank (19 pages)
- Steam Traps (6 pages)
- X100 – Inhibitor (4 pages)
- AM Series Boiler User Manual (156 pages)
- AM Series Boiler Cascade Sequencer Controller (26 pages)
- AM Series Boiler Modbus Interface Manual (18 pages)
- BMK 1.5 LN October 2012 (166 pages)
- BMK 1.5 LN July 2011 (152 pages)
- BMK 1.5 LN June 2010 (123 pages)
- BMK 1.5 LN May 2009 (111 pages)
- BMK 1.5 LN Dual Fuel Feb 2013 (162 pages)
- BMK 1.5 LN Dual Fuel June 2010 (139 pages)
- BMK 1.5 LN Dual Fuel Jan 2009 (126 pages)
- BMK 1500-2000 (188 pages)
- BMK 1500DF (196 pages)
- C-More Control Panel (162 pages)
- BMK 2.0 LN October 2012 (172 pages)
- BMK 2.0 LN Natural Gas (SN G-11-1861 and above) (170 pages)
- BMK 2.0 LN Nat. Gas June 2010 (125 pages)
- BMK 2.0 LN Natural Gas 2008 (111 pages)
- BMK 2.0 LN Nat. Gas for Mass. only (113 pages)
- BMK 2.0 LN Dual Fuel Serial G-11-2402 and UP (160 pages)
- BMK 2.0 LN Dual Fuel Nov 2010 (139 pages)
- BMK 2.0 LN Nat. Gas (112 pages)
- BMK 2.0 LN for Mass. only (114 pages)
- BMK 3.0 LN Dual-Fuel Series Gas Fired Low NOx Boiler System (136 pages)
- BMK 3.0 LN Natural Gas July 2011 (129 pages)
- BMK 3.0 LN Nat. Gas Jan 2011 (129 pages)