Burner Assembly Inspection and Maintenance Procedure – Continued

Figure 7-4b: Burner Assembly Mounting Details



Figure 7-5: Bare Burner and Replacement Gaskets Location

3/8”-16
HEX NUTS
(8 each)

5/16” x 1-3/4” BOLTS,

5/16” WASHERS &

NYLOCK NUTS

(4 each)

A/F

VALVE

PLENUM

AIR

FILTER

AIR/FUEL

VALVE

GAS

TRAIN

BLOWER
PLENUM

GAS INLET
PIPE

BLOCKED

INLET

SWITCH

BLOWER

PROOF

SWITCH

BLOWER

MANUAL
SHUT-OFF
VALVE

81183 – UPPER RELEASE GASKET
81166
– MIDDLE BURNER GASKET

81186 – LOWER RELEASE GASKET

BARE

BURNER

INSTALLED

IN HEAT

EXCHANGER

ASSY.

IMPORTANT!

Use ALL THREE gaskets provided, even if there

is only one existing gasket being replaced.

NOTE

The LOWER RELEASE

GASKET (P/N 81186) features

four tabs around its periphery.