beautypg.com

Op-02 battery – A&D Weighing HC-3Ki User Manual

Page 43

background image

41

12. OP-02 BATTERY

Using OP-02 SLA Battery

‰

The scale can operate with by an SLA (Sealed Lead Acid) battery that will be

commercially available.

‰

The scale (with no other options) can be operated for around 80 hours by fully

charged battery.

‰

The battery will take about 15 hours to be fully charged.

‰

The battery life will vary depending on how the scale is used, ambient temperature

and so on.























1. Disconnect the AC adapter from the scale.
2. Loosen the two M3 screws and remove the battery cover.
3. Connect the wires in the battery box to the battery.

Be sure to connect RED wire to positive (+ / RED) terminal and BLACK wire to
negative (- / BLACK) terminal. Or there is a risk of explosion.

4. Place the battery into the box and attach the battery cover using the screws

removed in the step 2 above.

5. Press the

ON/OFF

key and check if the scale works normally.



‰

Use a Yuasa Battery NP4-6 (6V, 4Ah).

‰

Use only the AC adapter that is provided with the HC-i scale.

‰

There will be risk of explosion if battery is connected

improperly or replaced with by an incorrect type.

‰

Dispose of the used battery according to the local laws and

regulations.

M3 screws

Battery NP4-6

“+” electrode (RED)

“-” electrode (BLACK)

Battery Cover

This manual is related to the following products: