4. ENTERING A TARE WEIGHT

There are two methods of tare operations.
‰

Using the

TARE

key to subtract the displayed container weight directly. Please

see “3-1. Basic Operations ”.

‰

Using the

KEYBOARD TARE

key to enter a tare weight via the 10-key pad.

4-1. Using the KEYBOARD TARE Key

1. Remove everything from the weighing pan and press the

ZERO

key to zero the

scale.


2. Press the

KEYBOARD TARE

key.

The weight display will blink (display is
any tare weight previously entered).







3. Use the

0

Æ

9

10-key pad to

display the desired tare weight.


‰

If you hit the wrong key, press

the

C

key to clear and start again.

(Example of a tare weight 615g)




4. Press the

ENTER

key.

The weight display changes to net
weight.

‰

The TARE ENTERED indicator will light.

















KEY-

BOARD

TARE

888.8.8.81

0

COUNT

WEIGHT UNIT WEIGHT

888

0.000

8

8

0.00000

0

00

888.8.8.81

0

COUNT

WEIGHT UNIT WEIGHT

888

0.615

8

8

0.00000

0

00

888.8.8.81

0

COUNT

WEIGHT UNIT WEIGHT

88

-0.615

8

8

0.00000

STABLE

TARE

ENTERED

ZERO

ENTER