1. Before Operation

1

12

1.4

Installation and Environment

This section describes the panel mounting method and precautions for installation.

Use environment

This section describes environment, location, and wiring precautions for the KV-
D20.

Locations

Avoid installing the KV-D20 in the following locations:

Locations in which the KV-D20 may be subjected to direct sunlight.

Locations in which the surrounding air temperature drops below 0

°

C or

exceeds 50

°

C.

Locations in which the relative humidity drops below 35% or exceeds 85%.

Locations in which condensation occurs due to sudden temperature drops.

Locations in which there are corrosive or flammable gases.

Locations exposed to dust, salt, metal particles, or greasy fumes.

Locations in which the KV-D20 may be directly subjected to vibration or
impact.

Locations in which water, oil, or chemicals may splash the KV-D20.

Locations in which a strong magnetic or electric field is generated.

Install the KV-D20 as far as possible from radio transmitters and receivers.
Radio waves generated by the KV-D20 may cause noises on these devices.

Precautions for improving noise immunity

Do not install the KV-D20 inside of a panel along with high-voltage equipment.

Install the KV-D20 as far as possible from power lines.

If the KV-D20 is installed near equipment that generates a strong electric or
magnetic field (e.g. solenoids, choppers, etc.), install it as far as possible from
the equipment.

Precautions for operability and maintenance
To improve safety during operation and maintenance, install the KV-D20 as far
as possible from high-voltage equipment or power equipment.

Do not install the I/O signal lines in the same conduit as power lines or high
voltage lines. Otherwise, generated noise may cause malfunctions.
If noise causes flicker on the display of the KV-D20, provide ferrite cores on the
modular cable. (It is more effective to wrap the cable once around the ferrite
core.)

CAUTION

Modular cable supplied with the KV-D20

Ferrite cores