beautypg.com

Connection and wiring method, Connection to the communication unit, Connector pin alignment – KEYENCE SR-700 Series User Manual

Page 3: Rs-232c wiring

background image

3

E SR-700-IM

Connection and Wiring Method

Connection to the communication unit

Connect the connector to the communication
unit (N-R2/UB/R4/L1).
Refer to the communication unit instruction
manual for more details.

Connector pin alignment

* The shielded wire is connected to a signal ground.

It is possible to change the functions of the input terminals and output
terminals. Refer to the user's manual for making these changes.

Connecting the power

Input terminal 1 and Input terminal 2 wiring

These are non-voltage inputs. Connect relay contacts or NPN open collector
outputs.
• The TIMING and PRESET inputs are non-voltage inputs.

• TIMING (Input terminal 1) is input to initiate the 2D code and barcode

reading.

• PRESET (Input terminal 2) is input to preset (register) the 2D code and

barcode data on the SR-700 Series.

Output terminal 1, Output terminal 2, Output terminal 3

and Output terminal 4 wiring

These are NPN open collector outputs.

• OK (Output terminal 1) is output for a successful reading when a check

against preset data is successful.

• NG/ERROR output (Output terminal 2) is output for an unsuccessful

reading when a check against preset data fails.

• ERROR (Output terminal 3) is output for an unsuccessful reading.
• BUSY (Output terminal 4) is output when preset data registration has been

completed and internal processing is taking place.
When BUSY is output, TIMING (Input terminal 1) cannot be input.

RS-232C wiring

Use the following wiring when connecting to a PC or a PLC.

Pin no.

Wire color

Signal name

Description

Signal

direction

1

Transparent

OUT1

Output terminal 1

(Default value:

OK output)

Output

2

Gray

OUT2

Output terminal 2

(Default value:

NG/ERROR output)

Output

3

Purple

TxD

RS-232C send

Output

4

Blue

CTS

RS-232C send OK

Input

5

Lt. blue

OUT4

Output terminal 4

(Default value:

BUSY output)

Output

6

Yellow green

IN2

Input terminal 2

(Default value:

PRESET input)

Input

7

Brown

RxD

RS-232C receive

Input

8

Pink

RTS

RS-232C receive OK

Output

9

Orange

OUT3

Output terminal 3

(Default value:

ERROR output)

Output

10

Yellow

IN1

Input terminal 1

(Default value:

TIMING input)

Input

11

Red

5 V

5 V Power

12

Black

GND (SG)

Power GND/Signal GND

Do not use a reverse connection for the power supply. Doing so may

damage the unit.

Use a stable power supply that is 5 VDC +5%, -10%.

Using a power supply that exceeds this range may damage the unit.

6

10

5

9

4

2

1

8

12

11

3

7

RP17-13PA-12PC plug (male)

Made by Hirose Electric Co., Ltd.

GND

+5V

12

+

11

5 VDC

NOTICE

10kΩ

220Ω

IN

GND

12

6,10

With or
without
contacts

4.7kΩ

DC5V

Internal circuit

Internal circuit

GND

OUT

12

+

1, 2,
5, 9

Load

* Rated load: 24VDC (30mA) or less

4.7kΩ

47kΩ

33V

RxD(RD)

RxD

RTS(RS)

RTS

TxD(SD)

TxD

SR-700 Series

PC, PLC

D-sub 9-pin

(female)

#4-40 screw

Round

connector

12-pin

(female)

CTS(CS)

CTS

GND(SG)

GND

+5V

+

DTR(ER)

DSR(DR)

3

4

7

8

12

11

2

7

3

8

5

4

6