Checking the package contents, Part names and functions – KEYENCE SR-700 Series User Manual
Page 2
2
E SR-700-IM
FDA (CDRH) Regulations
This product complies with the following FDA (CDRH) regulations.
• FDA(CDRH) Part 1040.10, Class 1 Laser Product
The laser classification for FDA(CDRH) is implemented based on IEC60825-
1 in accordance with the requirements of Laser Notice No.50.
FCC Regulations
This product complies with the following FCC EMI regulations.
• FCC Part 15 Subpart B, Class A Digital Device
IC (Industry Canada) Regulations
This product complies with the following IC EMI regulations.
• ICES-003, Class A Digital Apparatus
Radio Waves Act in South Korea
Class A Equipment
This is a class A product. In a domestic environment this product may cause
radio interference in which case the user may be required to take adequate
measures.
Note: This caution is effective for the Korean Radio Act only.
A 급 기기 ( 업무용 방송통신기자재 )
이 기기는 업무용 (A 급 ) 전자파적합기기로서 판매자 또는 사용자는 이
점을
주의하시기 바라며 , 가정외의 지역에서 사용하는 것을 목적으로 합
니다 .
Checking the Package Contents
Part Names and Functions
1
E SR-700-IM
ULTRA-COMPACT Fixed Mount Code Reader
SR-700 Series
Instruction manual
Read this instruction manual before using the product in order to achieve
maximum performance.
Keep this instruction manual in a safe place after reading it so that it can be
used at any time.
Symbols
The following symbols alert you to important messages. Be sure to read
these messages carefully.
Important
It indicates cautions and limitations that must be followed during operation.
Point
It indicates additional information on proper operation.
Reference
It indicates tips for better understanding or useful information.
indicates the reference pages in this manual or the reference pages in separate manuals.
Safety Information for SR-700 Series
General Precautions
Safety precautions on Laser product
The SR-700 Series ULTRA-COMPACT Fixed Mount Code Reader uses a visible
semiconductor laser, with a wavelength of 660 nm, as a Laser pointer for
adjusting the reading position.
Laser Pointer Specifications
* The laser classification for FDA(CDRH) is implemented based on
IEC60825-1 in accordance with the requirements of Laser Notice No.50.
Follow the instructions mentioned in this manual. Otherwise, injury to the
human body (eyes and skin) may result.
Precautions on Proper Use
Precautions on Regulations and Standards
CE Marking
Keyence Corporation has confirmed that this product complies with the
essential requirements of the applicable EC Directive, based on the
following specifications. Be sure to consider the following specifications
when using this product in the Member State of European Union.
z EMC Directive (2004/108/EC)
Applicable standards
EMI : EN61326-1, Class A
EMS : EN61326-1
Remarks:
These specifications do not give any guarantee that the end-product with
this product incorporated complies with the essential requirements of
EMC Directive. The manufacturer of the end-product is solely responsible
for the compliance on the end-product itself according to EMC Directive.
z Low-voltage Directive (2006/95/EC)
Applicable Standard
EN60825-1,
Class 1 Laser Product
EN62471
CSA Certificate
This product complies with the following CSA and UL standards and has
been certified by CSA.
Applicable standards:
CAN/CSA C22.2 No.61010-1
UL61010-1
Be sure to consider the following specifications when using this product as a
product certified by CSA.
Overvoltage category
Use this product under pollution degree 2.
Use this product at the altitude of 2000 m or less.
Indoor use only.
When using this product, use the following power supply.
CSA or UL certified power supply that provides Class 2 output as defined
in the CEC (Canadian Electrical Code) and NFPA79 (NEC: National
Electrical Code), or
CSA or UL certified power supply that has been evaluated as a Limited
Power Source as defined in CAN/CSA-C22.2 No. 60950-1/UL60950-1.
Either PoE or 24V power supply shall be used.
The symbol
on the product means "Direct current".
It indicates a hazardous situation which, if not avoided, will result in death or
serious injury.
It indicates a hazardous situation which, if not avoided, could result in death
or serious injury.
It indicates a hazardous situation which, if not avoided, could result in minor
or moderate injury.
It indicates a situation which, if not avoided, could result in product damage
as well as property damage.
Do not use this product for the purpose to protect a human body or a part
of human body.
This product is not intended for use as explosion-proof product. Do not
use this product in a hazardous location and/or potentially explosive
atmosphere.
Be sure to check that the SR-700 Series performs properly before starting
the work or operation.
If the SR-700 Series malfunctions, take adequate safety precautions to
prevent various types of damage.
Do not use the SR-700 Series in a manner not specified herein. It may
result in fire, electric shock or malfunction.
It should be noted that functions and performances will not be guaranteed
if the SR-700 Series is used in any way not specified or described in the
product specifications or it is modified.
When the SR-700 Series is used in combination with other devices,
functions and performance may be degraded, depending on the operating
conditions and environment.
Wavelength
660 nm
Output
60
PW
Pulse duration
20 0
Ps
Laser class
Class 1 Laser Product
(IEC60825-1:2007, FDA(CDRH) Part 1040.10*)
Use of controls or adjustments or performance of procedures other than
those specified herein may result in hazardous radiation exposure.
Do not disassemble this product. The laser radiation emission from this
product is not automatically stopped when it is disassembled.
Precautions on Class 1 Laser Product
Do not stare into the direct or specularly reflected beam.
96M13107
DANGER
WARNING
CAUTION
NOTICE
WARNING
CAUTION
NOTICE
WARNING
Do not use a voltage other than 5VDC with the SR Series. Doing so may
lead to damage on the unit.
When using the dedicated communication units (NX-50CL, N-R2/R4/UB/
L1, or DV-90 Series), use a power supply within the appropriate range for
each unit.
Be sure to turn the power off to devices attached to the SR Series when
you plug or unplug the cables. Failure to do so may cause damage to the
SR Series.
Do not disassemble or modify the SR Series. Doing so may lead to
damage on the unit.
Keep the cables away from high-tension cables or power sources.
Otherwise, noise could cause malfunctions or accidents.
The SR Series is a precision instrument. Do
not apply shock to the instrument or drop it.
Be especially careful when transporting or
installing the unit.
Do not hold the SR eries by its cable. The
units may become damaged if they strike
each other.
Do not allow water, oil, dust, or other foreign substances to stick to the
scanner. This may cause read errors. Use a soft, dry cloth to wipe any
substances from the scanner. (Do not use a cloth dipped in alcohol or
other cleaning substance.)
NOTICE
Main unit (SR-700HA/SR-700/SR-710)
Instruction Manual
Mounting bracket x 1
Insulating spacer x 2
Washer x 2
Installation screws (M3) x 2
Name
Function
(1) Scanner
Reads 2D codes and barcodes.
(2) Cable
Cable length is 1.8 m.
(3) Connector
(Round connector)
Connects to the power supply and communication unit
(N-R2/UB/R4/L1). The connector can be used for serial
communications with external devices.
(4) USB Connector
Connects to a PC to change settings with AutoID Network
Navigator. The connector is type A. Cable length is 130 mm
from the section where the cable splits.
(5) USB connector cap
When the USB connector is not in use, place the cap on the
connector to prevent the entry of dust and contact with
surrounding metal objects.
(6) Cable holder
When the USB connector is not in use, place the USB cable
in the cable holder so that it does not move around.
(7) Multiple LED indicator
Displays the operation status including the bank number
upon successful decoding, reading stability and operation
mode.
(8) IN LED
Lights up when an input terminal is on.
(Default settings: Displays the Input terminal 1 state)
(9) OK/NG/ERR LED
• Lights green when a OK signal is output.
• Lights orange when an NG signal is output.
• Lights red when an ERROR signal is output.
(10) TUNE switch
Use this switch to perform the following operations. Refer to
the user manual for more details.
• Turn on the laser pointer for reading position adjustment
• Display registered parameter banks
(Up to10 banks can be registered.)
• Start parameter tuning
• Read all of the program codes
• Reset errors
(11) TEST switch
Use this switch to perform the following operations. Refer to
the user manual for more details.
• Start and stop test mode
• Run 1 reading operation
• Fix the communication settings to the default values when
sending and receiving the settings
(7) Multiple LED
indicator (9) OK/NG/ERR LED (10) TUNE switch
(11) TEST switch
(1) Scanner
(3) Connector
(round connector)
(2) Cable
(4) USB connector
(5) USB connector cap
(8) IN LED
(6) Cable holder