3-5 light interference prevention method, English, Warning – KEYENCE SL-CHS Series User Manual
Page 36
Chapter 2 Installation and Assembly
2-14
2
English
ENGLISH
2-3-5 Light Interference Prevention Method
This section explains how to install multiple units of the SL-CHS Series units without using the light
interference prevention cables prescrided in this instruction manual.
[Sensor installation location examples]
(1) Side by side
(2) Vertically stacked
(3) Parallel
(4) Separated by object
Tr
ansmitter
Receiv
er
Receiv
er
Tr
ansmitter
Tr
ansmitter
Receiv
er
Receiv
er
Tr
ansmitter
Receiv
er
Tr
ansmitter
Tr
ansmitter
Receiv
er
Receiv
er
Tr
ansmitter
Tr
ansmitter
Receiv
er
WARNING
To mount 2 or more sets of the of the SL-CHS Series without using the light
interference prevention cable specified in the instruction manual, install the SL-
CHS units as shown in the above diagrams, and then use the section 4
“Checklist”
(
➮ page 4-1) provided in the instruction manual to make sure the SL-CHS operates
properly. Not following this installation method could result in serious harm, such as
serious injury or death.