14

Communication Response Time

DRQ input

The data read in response to a DRQ input is the buffered data that DL-RS1A periodically retrieves
from the sensor amplifiers.
Therefore, the latest data detected by the sensors can only be read after T2 (DL-RS1A data
processing time) where DL-RS1A retrieves data from the sensor amplifiers.

Time chart

SW command and AW command

The SW and AW commands are write commands.

Time chart

When reading the data applied by settings written to the sensor amplifier with the SW
command or AW command, using the commands (M0, MS) or DRQ inputs, perform reading
after the above "T2 (DL-RS1A data processing time)" elapses.

Sensor amplifier

DL-RS1A

T1

T2

DRQ input

T5

T4

Detection

2 ms min.

T1: Sensor amplifier response time (Refer to the instruction manual of the sensor amplifier.)
T2: DL-RS1A data processing time
T4: DL-RS1A command processing time
T5: Response send time from DL-RS1A

* For the specific values (times) of T2 to T5, refer to

"Time Frames of Communication Response Time" (page 14).

External device

DL-RS1A

T5

T3

T4

Sensor amplifier

T6

T3: Command format send time from external device
T4: DL-RS1A command processing time
T5: Response send time from DL-RS1A
T6: Sensor amplifier setting change time

* For the specific values (times) of T3 to T6, refer to

"Time Frames of Communication Response Time" (page 14).

Point

Communication Response Time

Time Frames of Communication Response Time

This section describes the communication time frames (T2 to T6).

The maximum time required is shown for each time frame. However, depending on the
actual environment, it may require more time.

T2 (DL-RS1A data processing time)

For information on the calculation function, refer to the manual supplied with the sensor amplifiers.

When calculation function of sensor amplifiers is OFF

*

* This table also applies to the sensor amplifiers that do not have the calculation function.

When calculation function of sensor amplifiers is ON

T3 (Command send time from external device)

Refer to the manual supplied with the external device connected to DL-RS1A.

Reference

Number of connected

sensor amplifiers

Data processing time (T2)

FD-MH Series

1

7 ms

2

9 ms

3

13 ms

4

15 ms

5

19 ms

6

21 ms

7

25 ms

8

27 ms

9

31 ms

10

33 ms

Number of connected

sensor amplifiers

Data processing time (T2)

FD-MH Series

1

10.5 ms

2

13.5 ms

3

19.5 ms

4

22.5 ms

5

28.5 ms

6

31.5 ms

7

37.5 ms

8

40.5 ms

9

46.5 ms

10

49.5 ms