Parameters of Commands and Responses

*1

In the Data format column, "*" signifies a number from "0 to 9".

*2

Indicates that the data can only be read from (R), can only be written to (W), or can be both read
from and written to (R/W) the sensor amplifiers.

*3

Since each reset request is a level action, resets are continuously performed as long as the
value is set to 1.
Make sure you send a command format that writes 0 to the sensor amplifiers again after
receiving a response format.

*4

Regardless of the display mode specified on the sensor amplifiers, the range of configurable data
is the same as the "rESo" mode.

044

Integrated flow
quantity unit

-

*

1

R/W

2

045

Response time

*

1

R/W

0: 0.5
1: 1
2: 2.5
3: 5
4: 10
5: 30
6: 60

3

046

Display mode

*

1

R/W

0: Std
1: rESo

FD-MH10: 0
FD-MH50: 1

FD-MH100: 1
FD-MH500: 0

047

Hysteresis

FD-MH10

*.**

4

R/W

0.00 to 9.99

*4

0.10

FD-MH50

**.*

4

00.0 to 49.9

*4

00.5

FD-MH100

**.*

4

00.0 to 99.9

*4

01.0

FD-MH500

***.*

5

000.0 to 499.9

*4

005.0

048

Bank switching
function

-

*

1

R/W

0: OFF
1: ON

0

049

Flow indicator color

*

1

R/W

0: Red for ON, green for OFF
1: Green for ON, red for OFF

1

050

Power save mode

*

1

R/W

0: Do not use
1: Use

0

051

Analog output
selection

*

1

R/W

0: Standard
1: Free range analog

0

052

*7

Free range
analog lower limit

FD-MH10

**

2

R/W

00 to 20 (Configurable unit: 1)

00

FD-MH50

***

3

000 to 100 (Configurable unit: 5)

000

FD-MH100

***

3

000 to 200 (Configurable unit: 10)

000

FD-MH500

****

4

0000 to 1000 (Configurable unit: 50)

0000

053

*7

Free range
analog upper limit

FD-MH10

**

2

R/W

00 to 20 (Configurable unit: 1)

10

FD-MH50

***

3

000 to 100 (Configurable unit: 5)

050

FD-MH100

***

3

000 to 200 (Configurable unit: 10)

100

FD-MH500

****

4

0000 to 1000 (Configurable unit: 50)

0500

054

Keylock function

-

*

1

R/W

0: Unlock
1: Locked

0

060

Factory reset
(initialization)

*

1

R

0 - 1: Last written value

0

W

0 o 1: Perform initial reset

*8

Data

No.

Data name

Sensor

head

Data

format

*1

No. of

bytes

Attribute

*2

Data range

Initial value

Data

FD-MH10 FD-MH50

FD-MH100

FD-MH500

0

0.01

Cannot be set Cannot be set

Cannot be set

1

0.1

0.1

0.1

Cannot be set

2

1

1

1

1

3

10

10

10

10

4

100

100

100

100

5

Cannot be set

1000

1000

1000

6

Cannot be set Cannot be set Cannot be set

10000

Parameters of Commands and Responses

*5

When setting this value to 000.0, no alarm output is made even if the temperature falls below the
indicated temperature setting lower limit; an alarm output is made only when the temperature
exceeds the upper limit.

*6

When setting this value to 100.0, no alarm output is made even if the temperature exceeds the
indicated temperature setting upper limit; an alarm output is made only when the temperature falls
below the lower limit.

*7

To read or write this data type, the analog output of the sensor amplifiers must be set to "Free range
analog" (using data number 051).
Changing the Free range analog upper limit/lower limit is invalid when the analog output is set to
"Standard".

*8

The command is executed only when the setting of the sensor amplifiers is changed from 0 to 1. To
re-execute the command, first change the setting to 0, then change it to 1.

Control outputs

This parameter is used with communication command "MS" and DRQ input. Specify the ON/OFF
state of the control output, integrated pulse output, and error alarm output using a one-digit value
(ASCII character).

Data

Description

0

Outputs 1, 2, 3 OFF

1

Output 1 ON, 2 OFF, 3 OFF

2

Output 1 OFF, 2 ON, 3 OFF

3

Output 1 ON, 2 ON, 3 OFF

4

Output 1 OFF, 2 OFF, 3 ON

5

Output 1 ON, 2 OFF, 3 ON

6

Output 1 OFF, 2 ON, 3 ON

7

Outputs 1, 2, 3 ON