Parameters of Commands and Responses

This section describes the parameters used with various commands and responses.

Electromagnetic Digital Flow Sensor FD-MH Series

Communication commands

There are two types of communication commands: read commands and write commands.

ID numbers

This parameter is used with communication commands "SR" and "SW". Specify the ID number of the
target sensor amplifier using two digits (ASCII characters).
Example: Sensor amplifier of ID number 00 = 00, sensor amplifier of ID number 07 = 07

Communication

command

Attribute

Description

SR

Read

Reads the data for the specified data number from the sensor amplifier with the

specified ID number.

M0

Reads all of the instantaneous flow rate (current value) data that DL-RS1A

periodically retrieves from all sensor amplifiers.

MS

Reads the control output state and instantaneous flow rate (current value) data

that DL-RS1A periodically retrieves from all sensor amplifiers.

DR

Reads the control output state and instantaneous flow rate (current value) data

that DL-RS1A periodically retrieves from all sensor amplifiers when a DRQ input

is received.

SW

Write

Writes setting data for the specified data number into the sensor amplifier with

the specified ID number.

AW

Writes setting data for the specified data number into all sensor amplifiers.

Parameters of Commands and Responses

Data numbers

Specify the data number using three digits (ASCII characters).

Read-only data

The following table lists the types of data that can only be read from FD-MH Series sensor amplifiers.

Writing read-only data results in a communication error (error number: 22).

*1

In the Data format column, "*" signifies a number from "0 to 9".

Point

Data

number

Data name

Sensor head

Data format

*1

Number

of bytes

Attribute

*2

Data range

000

Instantaneous flow rate

(current value)

FD-MH10

**.**

5

R

00.00 to 99.99

*3

FD-MH50

FD-MH100

***.*

5

000.0 to 999.9

*3

FD-MH500

****.*

6

0000.0 to 9999.9

*3

001

Integrated flow quantity

FD-MH10

*******.**

10

R

0000000.00 to 4294967.29

*4

FD-MH50

FD-MH100

********.*

10

00000000.0 to 42949672.9

*4

FD-MH500

*********

9

000000000 to 429496729

*4

002

Instantaneous flow rate

(peak hold value)

FD-MH10

**.**

5

R

00.00 to 99.99

*3

FD-MH50

FD-MH100

***.*

5

000.0 to 999.9

*3

FD-MH500

****.*

6

0000.0 to 9999.9

*3

003

Instantaneous flow rate

(bottom hold value)

FD-MH10

**.**

5

R

00.00 to 99.99

*3

FD-MH50

FD-MH100

***.*

5

000.0 to 999.9

*3

FD-MH500

****.*

6

0000.0 to 9999.9

*3

005

Control output,

integration pulse

output,

error alarm output

states

-

*

1

R

0: Outputs 1, 2, 3 OFF

1: Output 1 ON, 2 OFF, 3 OFF

2: Output 1 OFF, 2 ON, 3 OFF

3: Output 1 ON, 2 ON, 3 OFF

4: Output 1 OFF, 2 OFF, 3 ON

5: Output 1 ON, 2 OFF, 3 ON

6: Output 1 OFF, 2 ON, 3 ON

7: Outputs 1, 2, 3 ON

006

Integration reset input

or bank switching input

*

1

R

0 : Off

1 : On

007

Bank switching state

*

1

R

0: Bank A

1: Bank B

008

Sensor amplifier error

state

****

4

R

0 to 1149

*5

010

Connected

sensor head

*

1

R

0

*6

: FD-MH10

1

*6

: FD-MH50

2

*6

: FD-MH100

3

*6

: FD-MH500

011

Temperature sensor

connection

*

1

R

0

*6

: Not connected

1

*6

: Connected

015

Temperature (current

value)

***.*

5

R

000.0 to 999.9

*7

016

Temperature

(peak hold value)

***.*

5

R

000.0 to 999.9

*7

017

Temperature

(bottom hold value)

***.*

5

R

000.0 to 999.9

*7