Connecting the Unit to Sensor Amplifiers

Connecting the Unit to Sensor Amplifiers

You use DL-RS1A by connecting it to sensor amplifiers. The connection method varies according to
the mounting type of the sensor amplifiers.
Before connecting DL-RS1A, you must install the main unit and expansion units of the sensor
amplifiers. For installation method, see the operating instructions for the SK-1000 Series.

„ Available sensor amplifiers

Make sure that the sensor amplifiers are turned off before connecting the RS-
232C communication unit DL-RS1A to them. Connecting the unit while the
sensor amplifiers are turned on may damage the unit.

Name

Type of amplifier

Main unit

Expansion unit

Max. connectable number

SK-1000 Series

DIN-rail mount

SK-1000

SK-1050

8 units
(Main: 1, Expansion: 7)

NOTICE

Connecting the Unit to Sensor Amplifiers

„ Connecting the DL-RS1A to DIN rail mount sensor amplifiers

1

Remove the expansion protective cover from the sensor amplifier that you want to connect to

the DL-RS1A.

2

Mount the DL-RS1A on the DIN rail and connect it to the sensor amplifier.

Make sure there is no space between the unit and the sensor amplifier.

3

Mount the end units (OP-26751, two units included) on either side of the sensor amplifier and

DL-RS1A unit and tighten the two screws on the top of each end unit.

(You can mount the end units in the same way you mount DL-RS1A.)

Sensor amplifier

Expansion protective cover

Sensor amplifier

DL-RS1A

Connector

Check that the sensor amplifier connector (for DIN

rail mounting) located on the side of DL-RS1A is

not installed at an angle as shown in the

illustration to the right. Connecting the unit with

its connector installed at an angle to a sensor

amplifier may damage the unit.

NOTICE

Sensor amplifier connector

RS-232C communication unit DL-RS1A

End unit

End unit

Make sure you firmly insert DL-RS1A all the way into the sensor amplifier.

Turning the power on when the unit is not inserted straight or firmly connected

may damage the unit.