beautypg.com

Communication response time, Communication response time and time chart – KEYENCE DL-RS1A User Manual

Page 16

background image

14

Communication Response Time

This section describes the communication response time for each communication command and
various time frames.

Communication Response Time and Time Chart

This section describes the concept of communication response time and the time chart for the
communication commands.

When sending communication commands consecutively from the external device, wait to send
the next command after reception of the response for the previous command from DL-RS1A
completes.

„ SR command

The SR command directly reads data from a sensor amplifier during T4 (DL-RS1A command
processing time).

Time chart

„ M0 command and MS command

The M0 and MS commands read the buffered data that DL-RS1A periodically retrieves from the
sensor amplifiers.
Therefore, the latest data detected by the sensors can only be read after T2 (DL-RS1A data
processing time) where DL-RS1A retrieves data from the sensor amplifiers.

Point

External device

DL-RS1A

T5

T3

T4

T3: Command format send time from external device
T4: DL-RS1A command processing time
T5: Response send time from DL-RS1A

* For the specific values (times) of T3 to T5, refer to

"Time Frames of Communication Response Time" (page 17).

Sensor amplifier


DL-RS1A

T1

T2

External device

T3

T5

T4

T1: Sensor amplifier response time (Refer to the SK-1000 Series instruction manual.)
T2: DL-RS1A data processing time
T3: Command format send time from external device
T4: DL-RS1A command processing time
T5: Response send time from DL-RS1A

Detection

* For the specific values (times) of T2 to T5, refer to

"Time Frames of Communication Response Time" (page 17).

Communication Response Time

„ DRQ input

The data read in response to a DRQ input is the buffered data that DL-RS1A periodically retrieves
from the sensor amplifiers.
Therefore, the latest data detected by the sensors can only be read after T2 (DL-RS1A data
processing time) where DL-RS1A retrieves data from the sensor amplifiers.

Time chart

„ SW command and AW command

The SW and AW commands are write commands.

Time chart

Sensor amplifier


DL-RS1A

T1

T2

DRQ input

T5

T4

Detection

2 ms min.

T1: Sensor amplifier response time (Refer to the SK-1000 Series instruction manual.)
T2: DL-RS1A data processing time
T4: DL-RS1A command processing time
T5: Response send time from DL-RS1A

* For the specific values (times) of T2 to T5, refer to

"Time Frames of Communication Response Time" (page 17).

External device

DL-RS1A

T5

T3

T4

Sensor amplifier

T6

T3: Command format send time from external device
T4: DL-RS1A command processing time
T5: Response send time from DL-RS1A
T6: Sensor amplifier setting change time

* For the specific values (times) of T3 to T5, refer to