6 dp-v1 service, Ex ec ut in g c om m uni ca tion – KEYENCE DL-PD1 User Manual
Page 56

3-6
DP-V1 Service
3-32
- PROFIBUS DP Compatible Network Unit DL-PD1 User's Manual (GT2) -
Ex
ec
ut
in
g C
om
m
uni
ca
tion
3
132
Response time
DINT
R/W
3
When the
connected
sensor head is
GT2-H***/A***
When the
connected
sensor head
is GT2-P***
0: HSP (3.0 ms)
1: 5 ms
2: 10 ms
3: 100 ms
4: 500 ms
5: 1000 ms
HSP (12 ms)
20ms
40ms
400ms
2000ms
4000ms
133
Timing type
DINT
R/W
0
0: External timing input
1: Rising self
2: Falling self
134
Self-timing level
DINT
R/W
+000.5000 -199.9999 to +199.9999
135
Self-timing delay type
DINT
R/W
0
0: Static hold
1: Delay timer
136
User-specified delay time
DINT
R/W
1000
0000 to 9999
137
Static hold determination
DINT
R/W
0
0: Default
1: User
138
Static hold stable range
DINT
R/W
+000.0100 000.0000 to +199.9999
139
Measurement direction
DINT
R/W
0
0: Normal
1: Reverse
140
Multiplier
DINT
R/W
001.0
000.1 to 100.0
141
Output mode
DINT
R/W
0
0: NO
1: NC
142
Display resolution
DINT
R/W
0
0: 0.0001
1: 0.001
2: 0.01
3: 0.1
143
Hysteresis
DINT
R/W
+000.0030 000.0000 to +199.9999
144
Simultaneous input setting
*12
DINT
R/W
0
0: Individual input
1: Simultaneous input
145
Special output setting
*8
DINT
R/W
0
0: Do not use
1: 5-output
2: Limit output
3: Limit output user setting
4: All GO
5: All limit output
146
Limit output HH position
*8
DINT
R/W
000.0000
-199.9999 to +199.9999
147
Limit output LL position
*8
DINT
R/W
000.0000
-199.9999 to +199.9999
148
Select preset data
DINT
R/W
0
0: R.V. value
1: P.V. value
149
Preset memory
DINT
R/W
0
0: YES
1: NO
150
Preset point
DINT
R/W
0
0: Common to all banks
1: Store separately for each bank
151
Power-saving function (ECO)
DINT
R/W
0
0: OFF
1: HALF
2: ALL
152
Jam detection function
DINT
R/W
0
0: OFF
1: ON
2: USER
153
Jam detection position
DINT
R/W
+000.5000 -199.9999 to +199.9999
Index
(DEC)
Function name
Description
Data
type
Attribute
Default
value
Value