0396H
(918)
Bank switching
method
Set up method for switching the Bank.
Parameter range: 0 to 1 (initial value: 0)
0:Button
1:External input
R/W
DINT
0397H
(919)
(Reserved for system)
0398H
(920)
Zero shift value
memory
function
Set up whether to save the zero-shift state.
Parameter range: 0 to 1 (initial value: 0)
0: OFF
1: ON
R/W
DINT
0399H
(921)
(Reserved for system)
039AH
(922)
Display digit
Set up display digit. (initial value: 0)
0:Initial state
1:0.001
2:0.01
3:0.1
4:1
R/W
DINT
039BH
(923) to
039FH
(927)
(Reserved for system)
Group5
03A0H
(928)
Group5
Entry count
Indicates the No. of Group 5 entries.
Parameter range: 4
R
DINT
03A1H
(929)
Distance
correction
method
Set the distance correction method.
Parameter range: 0 to 1 (initial value: 0)
0: Initial state
1: User setting
R/W
DINT
03A2H
(930)
Near-side
distance
correction
amount
Set the near-side distance correction amount.
Parameter range: 5 to 50
(initial value: 25)
R/W
DINT
03A3H
(931)
Far-side
distance
correction
amount
Set the far-side distance correction amount.
Parameter range: 60 to 120
(initial value: 100)
R/W
DINT
03A4H
(932)
Area scaling
Set the area scaling.
Parameter range: 0.10 to 1.50
(initial value: 1.00)
R/W
DINT
03A5H
(933) to
03BFH
(959)
(Reserved for system)
Group6
03C0H
(960)
Group6
Entry count
Indicates the No. of Group 6 entries.
Parameter range: 11
R
DINT
03C1H
(961)
Product code
Indicates the product code.
Main unit
: 4024
Expansion unit : 4025
R
DINT
03C2H
(962)
Revision
Indicates the revision.
The higher-order bytes in the lower-order word
indicate the major revision and the lower-order
bytes indicate the minor revision.
Parameter range: 0101H
R
DINT
03C3H
(963)
Connected
sensor head
Indicates model of sensor head connected to
the amplifier.
0:Not connected
1:The head is connected
R
DINT