KEYENCE DL-EP1 User Manual
Page 52

- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (SK-1000) -
3-4 Message Communication
3-24
3
Commu
nic
ati
ng
wi
th t
he SK-1000
S
eries
(2) Writing data to a sensor amplifier
Message communication writes parameters to the DL-EP1 and the sensor
amplifier connected to the DL-EP1.
"(2) Writing parameters to a sensor amplifier" (Page 3-47)
(3) Issuing operation commands to a sensor amplifier
Message communication issues operation commands such as zero shift to the DL-
EP1 and the sensor amplifiers connected to the DL-EP1.
"(3) Issuing operation commands to a sensor amplifier" (Page 3-48)
(4) Locking sensor amplifier operations
Message communication locks operations by keys on the sensor amplifier
connected to the DL-EP1.
"(4) Locking sensor amplifier operations" (Page 3-50)
Command:
1
Response
Hold function of the SK:
Sample hold Peak hold
DL-EP1
Scanner
Service code: 10H
Class ID: 67H
Instance ID: 01H
Attribute ID: 0388H (904)
Service data: 1
SK
Command
Response
The SK executes an operation assigned to
external input 1.
DL-EP1
Scanner
Service code: 4BH
Class ID: 67H
Instance ID: 01H
Attribute ID: 0301H(769)
SK
Command
Response
Changes using the
sensor amplifier keys are locked.
DL-EP1
Scanner
Service code: 4CH
Class ID: 67H
Instance ID: 00H
Service data: 01H
SK