6

IA Series-IM_E

z Zero shift input

When external input is input, the current value is shifted by the value set for zero.

„

5. Analog output scaling (Bank A/B)

With the factory default setting (

dEFLt), the analog output is provided shown

below.

Default value

If the clamp function is set to on (see "3. Clamp function setting") and values
are held, the analog output changes according to the displayed value.

The output is 0.2 V if measurement cannot be made or an error occurred.

„

6. Upper limit setting of scaling (Bank A/B)

Sets the upper limit of analog output scaling.

This setting can only be made when "FrEE" is selected in "5. Analog output
scaling (Bank A/B)"

„

7. Lower limit setting of scaling (Bank A/B)

Sets the lower limit of analog output scaling.

This setting can only be made when "FrEE" is selected in "5. Analog output
scaling (Bank A/B)"

„

8. Eco display setting

Set this parameter to reduce the consumption current or to stop displaying
specific values.
The main screen switches to eco mode if no operations take place for 30 seconds.

During the eco display, operating either button returns to the normal display.

Output circuit

* The power 0 V (blue line) and voltage output

GND (shielded) are common inside.

Input circuit

Purple line . . . Laser emission stop input
Pink line. . . . . External input function

*

* The external input can be set to one of

the following.

Bank switching input

Zero shift input

Not used

* The minimum input time is 20 ms.

Pressing the [Up] and [Down] arrow buttons simultaneously for at
least three seconds cancels the zero point.

When the zero shift is performed using the external input, if
the power is turned OFF, the previous state before the zero
shift function is restored.

Model

Analog voltage output (4 to 0.5 V)

IA-030

25 to 35 mm

IA-065

55 to 75 mm

IA-100

80 to 120 mm

Setting item

Description

Default value

Upper limit of
scaling (4 V)

-99.999 to +99.999 (Unit: mm)

IA-030:5.000

IA-065:10.000
IA-100:20.000

Setting item

Description

Default value

Lower limit of
scaling (0.5 V)

-99.999 to +99.999 (Unit: mm)

IA-030:-5.000

IA-065:-10.000
IA-100:-20.000

Reference

Point

Measurement distance
(mm)

0.5V

2.25V

4V

analog voltage

output

19.5 25

Current value of the
amplifier unit (mm)

10.500 5.000

0

-5.000

-15.500

30 35

45.5

IA-030

0.2V

0.5V

2.25V

4V

54.4

55

10.600 10.000 0

-10.000

-40.600

65 75

105.6

IA-065

0.2V

Measurement distance
(mm)

analog voltage

output

Current value of the
amplifier unit (mm)

0.5V

2.25V

4V

74.4

80

25.600

20.000 0

-20.000 -30.600

100 120

130.6

IA-100

0.2V

Measurement distance
(mm)

analog voltage

output

Current value of the
amplifier unit (mm)

Setting item

Description

Default value

on

The digital display and bar display indicators are
turned off.

oFF

Turns off the eco display.

{

bAr

Turns off the digital display.

Error Displays and Corrective Actions

Error indication

Error contents

Remedy

Head error

Sensor head is not
connected.
Head cable is broken.
Sensor head is damaged

• Check that the sensor head is

connected.

• Check that the head cable is not broken.
• Check the connection of the head

cable to the connector.

• After checking these points, turn on

the power again.

EEPROM error

Data read/write error

Perform the initial reset (initialization).

Data has been written in
the EEPROM over 1
million times and can no
longer be updated.

If you need to write more data,
replace the amplifier unit.

There is no workpiece or
background within the
measurement distance
range, or no light is
entering the receiver.

Set a workpiece or background in the
distance for detection from the sensor.

Reading exceeds the
measurement distance
range.

Set a workpiece or background in the
distance for detection from the sensor.

Light intensity is saturated.

Tilt the sensor head so that specular
reflection does not enter the sensor.

Troubleshooting

Problem

Cause and solutions

The external input does
not function.

Check the settings for the external input.

"4. External input setting" (page 5)

The current settings can no
longer be determined. The
user wants to return the
unit to the factory defaults.

Perform initial reset (initialization).

"" (page 4)

I/O Circuit Diagram

10 to 30 VDC

0V*

Brown

Blue

Black

Analog voltage
output (0.5 to 4 V)

Analog voltage*
output (GND)

Shielded

Sensor main circuit

(Short-circuit current 1 mA max.)

PLC etc.

Purple/pink (input)

Sensor main circuit

Blue *

5 V DC

0 V