M8 connector type, Lv-n11cn / n12cn, Lv-n11cp / n12cp – KEYENCE LV-N10 Series User Manual
Page 8: Socket cable (sold separately), Monitor output type, Lv-n11mn, Function configuration, Basic setting, Detection settings (func), Display settings (disp)
8
M8 Connector Type
Socket Cable (Sold Separately)
For LV-N11Cx / N12Cx
Monitor Output Type
Function Configuration
See "LV-N10 Series User's Manual" for details on each function.
Basic Setting
*1
cannot be selected when LV-S31/S62/S63 is connected.
*2 You can press the
button to set between the range of
and
.
Detection Settings (Func)
*1 Press the
button to set between the range of
and
(ms).
*2 Press the
button to set the adjustment sensitivity to a range of between
and
and set the warning output level to a range of between
and
.
*3 Cannot be selected when LV-S31 is connected.
*4 Press the
button to toggle between
/
/
.
*5 The analog output upper limit can be set between
and
. Refer to the "LV-N10 Series
User's Manual" for the operation method of analog output in respect to the preset display.
*6 Not available for zero line types.
*7 Monitor output type only (LV-N11MN).
Display Settings (diSP)
*1 Press the
button to toggle between
/
/
/
/
.
*2 Press the
button to set between the range of
and
.
LV-N11CN / N12CN
LV-N11CP / N12CP
Input / output circuit diagram
Input / output circuit diagram
*1 LV-N11CN only
*1 LV-N11CP only
LV-N11MN
10-30 VDC
3.3 VDC
(Control output)
PLC, etc.
*1
*1
0V
Short-circuit current
1 mA or less
Sensor main circuit
Ov
ercurrent protection circuit
Load
10-30 VDC
(Control output )
PLC, etc.
Short-circuit current
2 mA or less
0V
S
en
s
or m
a
in circ
u
it
Ov
erc
urrent protection circ
uit
Lo
a
d
1
2
3
4
M8 connector pin layout
1
2
3
4
M8 connector pin layout
OP-73864
(Cable length: 2 m)
OP-73865
(Cable length: 10 m)
1
2
3
4
Connected
pin No.
Pin and wire color table
1
Brown
2
3
4
White
Blue
Black
Wire color
10-30 VDC
Device
Impedance:10 k
Ω
or more
3.3 VDC
BlackControl output 1
(1-5 V)
PLC, etc.
Short-circuit current
mA or less
Orange
0V
Protection circuit
S
en
s
or m
a
in circ
u
it
Ov
erc
urrent protection circ
uit
Lo
ad
Monitor output
Pink
Blue
Brown
MODE
MODE
MODE
MODE
6WT$
5W24
7.64
/')#
J52
(KPG
5V)
5V)
5V)
5'6
5VF
5'V2
15'V
'0&
(W0E
&K52
5;5
5'6
5'6
MODE
Press and hold for 3 seconds or more
TURBO mode
SUPER mode
ULTRA mode
MEGA mode
HIGH SPEED mode*
1
FINE mode
Normal sensitivity setting method
Percentage Calibration*
2
Zero-shift calibration
Settings complete
Go to detection setup mode
Go to display setup mode
Go to system setup mode
Return to normal display
MODE
MODE
6
Settings complete
Go to display setup mode
Go to system setup mode
Return to detection
setup mode
Normal (light intensity)
detection mode
DATUM1 mode *
2
*
3
Timer OFF
Off-delay timer *
1
On-delay timer *
1
One-shot timer *
1
DATUM2 mode *
2
*
3
Area detection mode
Rising Edge Detection Mode *
3
Falling Edge Detection Mode *
3
External input off
External calibration input
Preset input
Zero shift input
Reset input
Light transmission OFF input
Pause mode transition input *
4
Sleep mode transition input
Return to normal display
Analog scaling
*5
7
Alternate
display
MODE
MODE
MODE
Normal display method
Reverse display
Settings complete
Go to system setup mode
Go to detection setup mode
Return to display setup mode
Sub-display off
Extension display
Bar display
Excess gain (%) display
Light intensity hold display *
1
Excess gain hold (%) display *
1
L-on / D-on display
Disable the saturation of the
Preset function
Enable the saturation of the
Preset function *
2
Return to normal display
MODE
MODE