beautypg.com

M8 connector type, Lv-n11cn / n12cn, Lv-n11cp / n12cp – KEYENCE LV-N10 Series User Manual

Page 8: Socket cable (sold separately), Monitor output type, Lv-n11mn, Function configuration, Basic setting, Detection settings (func), Display settings (disp)

background image

8

M8 Connector Type

Socket Cable (Sold Separately)

For LV-N11Cx / N12Cx

Monitor Output Type

Function Configuration

See "LV-N10 Series User's Manual" for details on each function.

Basic Setting

*1



cannot be selected when LV-S31/S62/S63 is connected.

*2 You can press the

button to set between the range of



and



.

Detection Settings (Func)

*1 Press the

button to set between the range of

and



(ms).

*2 Press the

button to set the adjustment sensitivity to a range of between



and



and set the warning output level to a range of between



and



.

*3 Cannot be selected when LV-S31 is connected.

*4 Press the

button to toggle between



/



/



.

*5 The analog output upper limit can be set between



and



. Refer to the "LV-N10 Series

User's Manual" for the operation method of analog output in respect to the preset display.

*6 Not available for zero line types.
*7 Monitor output type only (LV-N11MN).

Display Settings (diSP)

*1 Press the

button to toggle between



/



/



/



/



.

*2 Press the

button to set between the range of



and



.

LV-N11CN / N12CN

LV-N11CP / N12CP

Input / output circuit diagram

Input / output circuit diagram

*1 LV-N11CN only

*1 LV-N11CP only

LV-N11MN

10-30 VDC

3.3 VDC

(Control output)

PLC, etc.

*1

*1

0V

Short-circuit current

1 mA or less

Sensor main circuit

Ov

ercurrent protection circuit

Load

10-30 VDC

(Control output )

PLC, etc.

Short-circuit current

2 mA or less

0V

S

en

s

or m

a

in circ

u

it

Ov

erc

urrent protection circ

uit

Lo

a

d

1

2

3

4

M8 connector pin layout

1

2

3

4

M8 connector pin layout

OP-73864
(Cable length: 2 m)

OP-73865
(Cable length: 10 m)

1

2

3

4

Connected

pin No.

Pin and wire color table

1

Brown

2

3

4

White

Blue

Black

Wire color

10-30 VDC

Device
Impedance:10 k

Ω

or more

3.3 VDC

BlackControl output 1

(1-5 V)

PLC, etc.

Short-circuit current

mA or less

Orange

0V

Protection circuit

S

en

s

or m

a

in circ

u

it

Ov

erc

urrent protection circ

uit

Lo

ad

Monitor output

Pink

Blue

Brown

MODE

MODE

MODE

MODE

6WT$

5W24

7.64

/')#

J52

(KPG

5V)

5V)

5V)

5'6

5VF

5'V2

15'V

'0&

(W0E

&K52

5;5

5'6

5'6

MODE

Press and hold for 3 seconds or more

TURBO mode

SUPER mode

ULTRA mode

MEGA mode

HIGH SPEED mode*

1

FINE mode

Normal sensitivity setting method

Percentage Calibration*

2

Zero-shift calibration

Settings complete

Go to detection setup mode

Go to display setup mode

Go to system setup mode

Return to normal display

MODE

MODE

6

Settings complete

Go to display setup mode

Go to system setup mode

Return to detection
setup mode

Normal (light intensity)
detection mode

DATUM1 mode *

2

*

3

Timer OFF

Off-delay timer *

1

On-delay timer *

1

One-shot timer *

1

DATUM2 mode *

2

*

3

Area detection mode

Rising Edge Detection Mode *

3

Falling Edge Detection Mode *

3

External input off

External calibration input

Preset input

Zero shift input

Reset input

Light transmission OFF input

Pause mode transition input *

4

Sleep mode transition input

Return to normal display

Analog scaling

*5

7

Alternate
display

MODE

MODE

MODE

Normal display method

Reverse display

Settings complete

Go to system setup mode

Go to detection setup mode

Return to display setup mode

Sub-display off

Extension display

Bar display

Excess gain (%) display

Light intensity hold display *

1

Excess gain hold (%) display *

1

L-on / D-on display

Disable the saturation of the
Preset function

Enable the saturation of the
Preset function *

2

Return to normal display

MODE