Sensor amplifier, Warranties and disclaimers – KEYENCE LV-N10 Series User Manual
Page 12
12
Sensor Amplifier
*1 The input time is 25 ms (ON) / 25 ms (OFF) only when external calibration input is selected.
*2 Increases 30 mW (1 mA) for HIGH SPEED Mode
*3 When usin
g
expansion units, the workin
g
ambient temperature will chan
g
e accordin
g
to the followin
g
conditions.
Always install on a DIN rail (installed on the metal plate) and keep the output current to 20 mA / unit or less.
1 or 2 units connected: - 20 to + 55°C; 3 to 10 units connected: - 20 to + 50°C; 11 to 16 units connected: - 20 to + 45°C
When usin
g
the 2 output type, one unit is counted as two units.
*4 When connectin
g
nine or more expansion units, ensure that the power volta
g
e is 20 V or more.
*5 It increases by 15% when connected to the LV-NH100/NH110/NH300. It dose not include the power consumption of the load.
Power consumption when expansion units are connected is the total power consumption of each amplifier unit.
Example: When one main unit (LV-N11N) is connected to 2 expansion units (LV-N12N) and they are used with LV-NH100 heads in HIGH SPEED mode.
(1.15 x 860mW x 1) + (1.15 x 860mW x 2) = 2967mW max.
*6 Use with the over current protection device which is rated 30 V or more and not more than 1 A.
*7 When an amplifier is connected to the LV-NH100,LV-NH110 or LV-NH300 and used in HIGH SPEED mode, the power consumption is maximum. (989mW for NPN or 1127mW for PNP)
*8 Response time will be doubled from the normal response time when Double is set.
WARRANTIES AND DISCLAIMERS
KEYENCE, at its sole option, will refund, repair or replace at no charge any
defective Products within 1 year from the date of shipment. Unless stated
otherwise herein, the Products should not be used internally in humans, for
human transportation, as safety devices or fail-safe systems.
EXCEPT FOR THE
FOREGOING, ALL EXPRESS, IMPLIED AND STATUTORY WARRANTIES,
INCLUDING WARRANTIES OF MERCHANTABILITY, FITNESS FOR A
PARTICULAR PURPOSE AND NONINFRINGEMENT OF PROPRIETARY
RIGHTS, ARE EXPRESSLY DISCLAIMED. KEYENCE SHALL NOT BE LIABLE
FOR ANY DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL OR OTHER
DAMAGES, EVEN IF DAMAGES RESULT FROM THE USE OF THE
PRODUCTS IN ACCORDANCE WITH ANY SUGGESTIONS OR INFORMATION
PROVIDED BY KEYENCE. In some jurisdictions, some of the foregoing warranty
disclaimers or damage limitations may not apply.
E 1101-3
Type
2 output
1 output
0-line
Monitor output
Cable / Connector
Cable
M8 connector
–
Cable
Main unit / Expansion unit
Main unit
Expansion unit
Main unit
Expansion unit
Expansion unit
Main unit
Model
NPN
LV-N11N
LV-N12N
LV-N11CN
LV-N12CN
LV-N10
LV-N11MN
PNP
LV-N11P
LV-N12P
LV-N11CP
LV-N12CP
–
Input/output
Control output
2 output
1 output
N/A
1 output
External input
1 input
1 input
N/A
1 input
Monitor output
N/A
1 output
Response time
80 μs (HIGH SPEED) / 250 μs (FINE) / 500 μs (TURBO) / 1 ms (SUPER) /4 ms (ULTRA) / 16 ms (MEGA)
* 80 μs cannot be selected when LV-S31 / S62 / S63 is connected.
Output operation
Li
g
ht-ON / Dark-ON
Timer function
Timer OFF, OFF delay, ON delay, One-shot
Timer variable (1 ms to 9999 ms) Maximum error to settin
g
value is ±10 % or less
Control output
NPN output
NPN open collector 30 V, Residual volta
g
e 1 V or less (Output current: 10 mA or less) / 2 V or less (Output current: 10 to 100 mA)
(Stand-alone) 1 output max: 100 mA or less, 2 output total: 100 mA or less
(Multiple connections) 1 output max: 20 mA or less
PNP output
PNP open collector 30 V, Residual volta
g
e 1.2 V or less (Output current: 10 mA or less) / 2.2 V or less (Output current: 10 to 100 mA)
(Stand-alone) 1 output max: 100 mA or less, 2 output total: 100 mA or less
(Multiple connections) 1 output max: 20 mA or less
Monitor output (Only LV-N11MN)
Volta
g
e output: 1 to 5 V, load resistance: 10 k
:
or more,
repeat accuracy: ± 0.5% of F.S.
Response time: 1ms (HIGH SPEED / FINE / TURBO),1.2 ms (SUPER), 1.8 ms (ULTRA), 4.2 ms (MEGA)
External input
Input time 2 ms (ON) / 20 ms (OFF) or more
*1
Expansion units
Up to 17 units can be connected in total. (The 2 output type is treated as two units.)
Protection circuit
Protection a
g
ainst reverse power connection, output overcurrent, and output sur
g
e
Number of
interference
prevention units
Connect with
other than LV-S31
HIGH SPEED: 0, FINE / TURBO / SUPER: 2, ULTRA / MEGA: 4
(These numbers double when "Double" is selected.)
*8
Connect with
LV-S31
FINE: 2, TURBO / SUPER / ULTRA / MEGA: 4 (These numbers double when "Double" is selected.)
*8
Ra
ted
Power volta
g
e
*4
24 VDC (operatin
g
volta
g
e 10-30 VDC (includin
g
ripple)), ripple (P-P) 10% or less, Class 2 or LPS
*6
Power
consumption
*5
NPN
Normal: 830 mW or less (at 30 V. 30 mA at 24 V, 56 mA or less at 12 V)
*2 *7
Eco on: 710 mW or less (at 30 V. 26 mA at 24 V, 48 mA or less at 12 V)
*2
Eco full: 550 mW or less (at 30 V. 21 mA at 24 V, 40 mA or less at 12 V)
PNP
Normal: 950 mW or less (at 30 V. 33 mA at 24 V, 60 mA or less at 12 V)
*2 *7
–
Eco on: 815 mW or less (at 30 V. 29 mA at 24 V, 52 mA or less at 12 V)
*2
Eco full: 650 mW or less (at 30 V. 24 mA at 24 V, 40 mA or less at 12 V)
Environmental
resistance
Operatin
g
ambient
temperature
- 20°C to + 55°C (no freezin
g
)
*3
Operatin
g
ambient
humidity
35 to 85% RH (no condensation)
Vibration resistance
10 to 55 Hz, compound amplitude 1.5 mm, 2 hours for each of X, Y, Z axes
Shock resistance
500 m/s
2
, 3 times for each of X, Y, Z axes
Material
Housin
g
Amplifier body and dust cover material: Polycarbonate
Cable
PVC
Housin
g
dimensions
H 32.6 mm
u
W 9.8 mm
u
L78.7 mm
Wei
g
ht
Approx. 75
g
Approx. 65
g
Approx. 20
g
Approx. 20
g
Approx. 20
g
Approx.75
g
2011
11526E 1022-4 96M11527