beautypg.com

1 fs-n series, Sensor amplifier network manual – KEYENCE NU/FS-N Series User Manual

Page 9

background image

1 FS-N Series

7

- Sensor Amplifier Network Manual -

CC-Link

DeviceNet

Name

Attribute

Data

type

Initial
value

Parameter range

Data

category

(Hex)

Data No.

(Hex)

InstID

AttrID

(Hex)

00

nn71

nn x 10+3

75

[Custom] Key Lock Status

R/W

INT

0

0: Unlock
1: Key Lock
2: PIN Code Lock
3: Communication Lock

nn72

76

[Custom] PIN Code

R/W

INT

0

0 - 9999

nn73

77

[Custom] Slide Switch Lock

R/W

INT

0

0: Unlock
1: Lock

nn74

78

[Custom] L-on/D-on (N.O./N.C.)

R/W

INT

0

0 : OUT1 : L-on / OUT2 : L-on
1 : OUT1 : D-on / OUT2 : L-on
2 : OUT1 : L-on / OUT2 : D-on
3 : OUT1 : D-on / OUT2 : D-on

nn75

79

[Custom] Power Mode

R/W

INT

1

0: HIGH SPEED (Response Time 50

μ

s)

1: FINE (Response Time 250

μ

s)

2: TURBO (Response Time 500

μ

s)

3: SUPER (Response Time 1ms)
4: ULTRA (Response Time 4ms)
5: MEGA (Response Time 16ms)

nn76

7A

[Custom] Sensitivity Setting

R/W

INT

0

0: Normal Sensitivity Setting
1: Percentage Calibration
2: Zero-shift Calibration

nn77

7B

[Custom] Percentage Carib.
Target Value

R/W

INT

- 10

- 99 - +99

nn78 -

nn7F

7C - 83 System reserved

-

-

-

-

nn80

nn x 10+4

64

Group4 Entry count

*1

R

INT

9

9

nn81

65

Output Timer (Output1)

R/W

INT

0

0: Timer Off
1: Off-delay Timer
2: On-delay Timer
3: One-shot Timer

nn82

66

Timer Value (Output1)

R/W

INT

10

1 - 9999

nn83

67

System reserved

-

-

-

-

nn84

68

Detection Mode (Output1)

R/W

INT

0

0: Normal Detection Mode
1: DATUM1 Mode
2: DATUM2 Mode
3: Area Detection Mode
4: Rising Edge Detection Mode
5: Falling Edge Detection Mode

nn85

69

DATUM Speed

R/W

INT

0

0: Level1 (Slow)
1: Level2 (Normal)
2: Level3 (Fast)

nn86

6A

DATUM Warning Level

R/W

INT

50

0 - 100

nn87

6B

Control Input

R/W

INT

0

0: Not use
1: External Calibration
2: Preset
3: Zero-shift
4: Reset
5: Transmission OFF
6: PAUSE Mode Transition
7: SLEEP Mode Transition

nn88

6C

PAUSE Mode

R/W

INT

0

0: Always OFF
1: Always ON
2: Keep Output

nn89

6D

Light Emission Power

R/W

INT

100

1 - 100

nn8A -

8F

6E - 73 System reserved

-

-

-

-

nn90

74

[Custom] Group4 Entry count

*1

R

INT

9

9

nn91

75

[Custom] Output Timer (Output1)

R/W

INT

0

0: Timer Off
1: Off-delay Timer
2: On-delay Timer
3: One-shot Timer

nn92

76

[Custom] Timer Value (Output1)

R/W

INT

10

1 - 9999

nn93

77

System reserved

-

-

-

-

nn94

78

[Custom] Detection Mode
(Output1)

R/W

INT

0

0: Normal Detection Mode
1: DATUM1 Mode
2: DATUM2 Mode
3: Area Detection Mode
4: Rising Edge Detection Mode
5: Falling Edge Detection Mode