The table below summarizes how many ID numbers are occupied by each model of
sensor amplifier.
Each ID number is assigned an output, setting value, current value, and external input.
The external input can be used after configuring the "Control Input"parameter
of each sensor. (By default, "Control Input" is set to "0: Not use.") The models
FS-N10/N12* do not have an external input wire, but they can utilize external
input via network by using a network unit.
Number of ID Numbers Occupied
Model
Number of ID numbers occupied
FS-N10
1
FS-N12*
1
FS-N14*
2
Connection example:
Network unit
1
FS-N14*
FS-N12*
FS-N10
CH1 CH2
3
4
2
ID number
Data Assignments
Model
Item
Ch1 (1st ID number)
Ch2 (2nd ID number)
FS-N10
FS-N12*
Output
Output
-
Setting value
Setting value of output
Current value
Received light intensity
External input
External input
FS-N14*
Output
Output 1
Output 2
Setting value
Setting value of output 1
Setting value of output 2
Current value
Received light intensity
(Not used)
External input
External input
(Not used)