1 fs-n series, Sensor amplifier network manual – KEYENCE NU/FS-N Series User Manual
Page 8
1 FS-N Series
6
- Sensor Amplifier Network Manual -
CC-Link
DeviceNet
Name
Attribute
Data
type
Initial
value
Parameter range
Data
category
(Hex)
Data no.
(Hex)
InstID
AttrID
(Hex)
00
nn30
nn x 10+1
74
Saturation Canceling
R
INT
0
0: Not Active
1: Active
nn31
75
Operation Mode
R
INT
0
0: RUN
1: LED_OFF
2: SLEEP
3: PAUSE
nn32
76
Operation Mode Setting
R/W
INT
0
0: RUN
1: LED_OFF
2: SLEEP
3: PAUSE
nn33
77
Recipe Select
R/W
INT
0
0: Initialize
1: Custom
2: Fall
3: Percentage Calibration
4: Zero-shift
5: MEGA
nn34 -
nn3F
78 - 83 System reserved
-
-
-
-
nn40
nn x 10+2
64
Group2 Entry count
*1
R
INT
7
7
nn41
65
Setting Value (OUTPUT1/Area
High)
R/W
INT
50
0 - 9999
nn42
66
Setting Value (Output2)
R/W
INT
50
0 - 9999
nn43
67
System reserved
-
-
-
-
nn44
68
Setting Value (Area Low)
R/W
INT
50
0 - 9999
nn45
69
System reserved
-
-
-
-
nn46
6A
System reserved
-
-
-
-
nn47
6B
Limit Setting Value
R/W
INT
0
0
nn48 -
nn4F
6C - 73 System reserved
-
-
-
-
nn50
74
[Custom] Group2 Entry count
*1
R
INT
7
7
nn51
75
[Custom] Setting Value
(OUTPUT1/Area High)
R/W
INT
50
0 - 9999
nn52
76
[Custom] Setting Value (Output2)
R/W
INT
50
0 - 9999
nn53
77
System reserved
-
-
-
-
nn54
78
[Custom] Setting Value (Area Low)
R/W
INT
50
0 - 9999
nn55
79
System reserved
-
-
-
-
nn56
7A
System reserved
-
-
-
-
nn57
7B
[Custom] Limit Setting Value
R/W
INT
0
0 - 9999
nn58 -
nn5F
7C - 83 System reserved
-
-
-
-
nn60
nn x 10+3
64
Group3 Entry count
*1
R
INT
7
7
nn61
65
Key Lock Status
R/W
INT
0
0: Unlock
1: Key Lock
2: PIN Code Lock
3: Communication Lock
nn62
66
PIN Code
R/W
INT
0
0 - 9999
nn63
67
Slide Switch Lock
R/W
INT
0
0: Unlock
1: Lock
nn64
68
L-on/D-on (N.O./N.C.)
R/W
INT
0
0: OUT1 : L-on / OUT2 : L-on
1: OUT1 : D-on / OUT2 : L-on
2: OUT1 : L-on / OUT2 : D-on
3: OUT1 : D-on / OUT2 : D-on
nn65
69
Power Mode
R/W
INT
1
0: HIGH SPEED (Response Time 50μs)
1: FINE (Response Time 250μs)
2: TURBO (Response Time 500μs)
3: SUPER (Response Time 1ms)
4: ULTRA (Response Time 4ms)
5: MEGA (Response Time 16ms)
nn66
6A
Sensitivity Setting
R/W
INT
0
0: Normal Sensitivity Setting
1: Percentage Calibration
2: Zero-shift Calibration
nn67
6B
Percentage Carib. Target Value
R/W
INT
10
- 99 - +99
nn68 -
nn6F
6C - 73 System reserved
-
-
-
-
nn70
74
[Custom] Group3 Entry count
*1
R
INT
7
7