1 fs-n series, Sensor amplifier network manual – KEYENCE NU/FS-N Series User Manual
Page 10
1 FS-N Series
8
- Sensor Amplifier Network Manual -
CC-Link
DeviceNet
Name
Attribute
Data
type
Initial
value
Parameter range
Data
category
(Hex)
Data
No.
(Hex)
InstID
AttrID
(Hex)
00
nn95
nn x 10+4
79
[Custom] DATUM Speed
R/W
INT
0
0: Level1 (Slow)
1: Level2 (Normal)
2: Level3 (Fast)
nn96
7A
[Custom] DATUM Warning Level
R/W
INT
50
0 - 100
nn97
7B
[Custom] Control Input
R/W
INT
0
0: Not use
1: External Calibration
2: Preset
3: Zero-shift
4: Reset
5: Transmission OFF
6: PAUSE Mode Transition
7: SLEEP Mode Transition
nn98
7C
[Custom] PAUSE Mode
R/W
INT
0
0: Always OFF
1: Always ON
2: Keep Output
nn99
7D
[Custom] Light Emission Power
R/W
INT
100
1 - 100
nn9A -
nn9F
7E - 83 System reserved
-
-
-
-
nnA0
nn x 10+5
64
Group5 Entry count *1
R
INT
5
5
nnA1
65
Output Timer (Output2)
R/W
INT
0
0: Timer Off
1: Off-delay Timer
2: On-delay Timer
3: One-shot Timer
nnA2
66
Timer Value (Output2)
R/W
INT
10
1 - 9999
nnA3
67
System reserved
-
-
-
-
nnA4
68
Detection Mode (Output2)
R/W
INT
0
0: Normal Detection Mode
1: Limit Setting Output
2: Warning Output
nnA5
69
Limit Output Mode
R/W
INT
0
0: Manual
1: Auto
nnA6 -
nnAF
6A - 73 System reserved
-
-
-
-
nnB0
74
[Custom] Group5 Entry count
*1
R
INT
5
5
nnB1
75
[Custom] Output Timer (Output2)
R/W
INT
0
0: Timer Off
1: Off-delay Timer
2: On-delay Timer
3: One-shot Timer
nnB2
76
[Custom] Timer Value (Output2)
R/W
INT
10
1 - 9999
nnB3
77
System reserved
-
-
-
-
nnB4
78
[Custom] Detection Mode (Output2)
R/W
INT
0
0: Normal Detection Mode
1: Limit Setting Output
2: Warning Output
nnB5
79
System reserved
-
-
-
-
nnB6
7A
System reserved
-
-
-
-
nnB7
7B
[Custom] Limit Output Mode
R/W
INT
0
0: Manual
1: Auto
nnB8
- BF
7C - 83 System reserved
-
-
-
-
nnC0
nn x 10+6
64
Group6 Entry count
*1
R
INT
6
6
nnC1
65
Display Reverse
R/W
INT
0
0: Normal
1: Reverse
nnC2
66
Sub Display
R/W
INT
0
0: None
1: Extension
2: Bar
3: Excess Gain(%)
4: Light Intensity HOLD
5: Excess Gain HOLD(%)
6: L-on/D-on
7: TAG Strings
*2
nnC3
67
Hold Display
R/W
INT
0
0: Normal
1: Peak Max. / Peak Min.
2: Bottom Max. / Bottom Min.
3: Peak Min. / Bottom Max.
4: Peak Max. / Bottom Min.