Outputting alarms, Error displays and corrective actions, Initializing, saving, and loading settings – KEYENCE PX-10 User Manual
Page 7: Limit setting function (page 7, no. 9), System settings menu
7
System Settings Menu
●
Initializing, Saving, and Loading Settings
■
Initializing settings (returns the parameters to the factory default state)
1
While pressing the
button, press the
button or the
button
five times.
2
With the
button or the
button, select "r S t " and press the
button.
3
With the
button or the
button, select ":n:t" and press the
button to perform initialization.
■
Saving settings (you can make changes but still return to the saved
settings)
1
While pressing the
button, press the
button or the
button
five times.
2
With the
button or the
button, select "SAvE" and press the
button.
3
With the
button or the
button, select "YES" and press the
button to save the settings.
* Saved settings are not cleared even when initialization is performed.
■
Loading saved settings
1
While pressing the
button, press the
button or the
button
five times.
2
With the
button or the
button, select "rSt" and press the
button.
3
With the
button or the
button, select "[vSt" and press the
button to load the saved settings.
Outputting Alarms
●
Limit Setting Function (Page 7, No. 9)
Limit settings output a warning when the difference in light intensity becomes too
small for detecting whether a workpiece is present.
• It can be used when "Limit Setting Function" is selected on page 7, No. 9.
There are two types of limit setting functions.
Peak value
This function samples the peak value when the light intensity rises above the set
value for detection output. The warning outputs when the minimum hold value
drops below the setting value for alarm output.
Bottom value
This function samples the bottom value when the light intensity falls below the set
value for detection output. The warning outputs when the maximum hold value
rises above the setting value for alarm output.
Resetting peak value and bottom value
Press and hold the
button and the
button for at least 3 seconds to
reset the values.
The function is reset when the power is turned off.
Error Displays and Corrective Actions
Select the setting by pressing the buttons.
.
Only displays the setting value and
the current value
.
Display can be switched
10
Display selection during detection (See page 5)
From the Basic Settings Menu
Select the setting by pressing the buttons.
.
Not to be used
.
Uses the display scaling function
.
Uses the display shift function
Display scaling target value setting
Select the setting by pressing the buttons.
The value can be set between 100
and 9900 in units of 100.
displays for the maximum
possible value.
When oFF
is selected
When
SCAL is
selected
8
Display value correction function selection
Select the setting by pressing the buttons.
.
Not to be used
.
Limit setting function
.
Reverse output
(Reverses the detection output)
Limit setting function selection
Select the setting by pressing the buttons.
.
Peak value setting
.
Bottom value setting
When oFF
or dobL is
selected
Current value after shifting
Shift value
When
LiMt is
selected
Alarm output selection
Select the setting by pressing the buttons.
.
OFF during normal operations,
ON during alarm
.
ON during normal operations,
OFF during alarm
.
ON during normal operations, switches
between ON and OFF during alarm
Alarm output value setting
Select the setting by pressing the buttons.
Select the setting value.
9
Alarm output setting
Setting the shift value
Adjust the setting by pressing the buttons.
Negative values are displayed as 0.
Select the setting by pressing the buttons.
.
Normal display
.
Reverses the display.
Even when the display is reversed,
the setting value is displayed in green and
the received light intensity is displayed in red.
11
Display reverse selection
Press
MODE
Press
MODE
Press
MODE
Press
MODE
Press
MODE
Press
MODE
Press
MODE
Press
MODE
Press
MODE
Press
MODE
Select the setting by pressing the buttons.
.
Saves power (Turns off the display).
During power save mode, only one segment in the
digital display lights up at a time and the lit
areamoves from one segment to the next in order.
(The display returns to normal display for one
minute when the keys are pressed.)
.
Normal display
12
Power save mode setting
To turn off all of the lights (both digital and operation display lights)
Press and hold the button for at least three
seconds to select
ALL
.
To revert to the normal method from ALL mode,
press the buttons at the same time
and hold them down for at least three seconds.
Return to section A
on the basic menu
Press
MODE
UP/DOWN
UP/DOWN
UP/DOWN
UP/DOWN
UP/DOWN
UP/DOWN
UP/DOWN
UP/DOWN
UP/DOWN
UP/DOWN
When ShFt
is selected
UP/DOWN
Error indication
Cause
Remedy
ErH
Sensor head is not connected.
There is a short circuit in the head
cable, or strong extraneous light has
entered the top of the short head.
Check whether there is a short
circuit in the head cable and
whether the amplifier is inserted
correctly.
Shield the sensor from the
extraneous light.
ErC
Overcurrent is flowing through the
output wire.
Check the load and reduce the
current to be within the rated range.
ErE
Data write/read error
Perform initialization.
Data has been written in the
EEPROM over 1 million times.
If you need to write more data,
replace the amplifier unit.
Err
The amplifier unit is broken.
Replace it with a new amplifier unit.
MODE
UP
DOWN
UP
DOWN
MODE
UP
DOWN
MODE
MODE
UP
DOWN
UP
DOWN
MODE
UP
DOWN
MODE
MODE
UP
DOWN
UP
DOWN
MODE
UP
DOWN
MODE
Bottom hold maximum value
Peak hold minimum value
Detection
output
Alarm output (PEAk parameter)
Parameter for PEAk selection
Parameter for botm selection
Setting value for detection output
Alarm output (botm parameter)
SET
MODE