Hardy HI 1746-WS User Manual
Page 78

HI 1746-WS WEIGH SCALE MODULE
6-4
15
Module Status Word
Bit
Module Status Bit
0
A/D Conversion Error
1
A/D Failure
2
Weight in lbs (0 = kgs)
3
Zero Tracking Enabled
4
Tare Enabled
5
Zero Enabled
6
Weight in Motion
7
No Calibration
8
Non-Volatile RAM Failure
9
Excitation Monitor
10
Communication Timeout
Error
11-13
Currently Not Used
14
Command Error
14 & 15
Currently Not Used
16
Relay Status
17
Firmware Revision
18
Gross Weight
(32 bit float, or integer)
MSW
19
Gross Weight
(32 bit float, or integer)
LSW
20
Net Weight
(32 bit float, or integer)
MSW
21
Net Weight
(32 bit float, or integer)
LSW
22
RoC (Rate of Change)
(32 bit float, or integer)
MSW
23
RoC (Rate of Change)
(32 bit float, or integer)
LSW
24
RoC Evaluation Period
WORD
PARAMETER
TABLE 6-1: BLOCK TRANSFER, READ