Hardy HI 1746-WS User Manual
Page 76

HI 1746-WS WEIGH SCALE MODULE
6-2
6
Setpoint 1 Mode
Bit
Setpoint Mode
0
ROC (Rate of Change)
1
Gross
2
Net
3
Gain Mode (0 = gain in wght)
(1 = loss in wght)
4
force low
5
force high
6
Excitation Error
7
No Excitation Error
8-15
Currently Not Used
7
Setpoint
2
Value (32 bit float, or integer)
MSW
8
Setpoint
2
Value (32 bit float, or integer)
LSW
9
Setpoint
2
Deadband (32 bit float, or integer)
MSW
10
Setpoint
2
Deadband (32 bit float, or integer)
LSW
11
Setpoint
2
Preact (32 bit float, or integer)
MSW
12
Setpoint
2
Preact (32 bit float, or integer)
LSW
WORD
PARAMETER
TABLE 6-1: BLOCK TRANSFER, READ